共找到 354 条与 工业与民用建筑工程综合 相关的标准,共 24 页
This part of ISO 15928 sets out a method for describing the structural serviceability performance of houses. It covers objectives, provides performance descriptions, establishes parameter descriptions and outlines evaluation processes. This part of ISO 15928 is intended for use in the evaluation of the design and construction of houses, in the international trading of houses or their sub-systems, and in developing risk-management tools for the protection of houses. method and/or criteria. NOTE 1 Annex A includes background information on this part of ISO 15928, guidance on its use, and suggestions on good practice. NOTE 2 NOTE 3 Details on references referred to in Notes are provided in a Bibliography. Structural safety, durability and other attributes are covered in other parts of ISO 15928.
Houses - Description of performance - Part 2: Structural serviceability
This part of ISO 15928 sets out a method for describing the structural durability performance of houses. It covers objectives, provides performance descriptions, establishes parameter descriptions and outlines evaluation processes. This part of ISO 15928 is intended for use in the evaluation of the design and construction of houses, in the international trading of houses or their subsystems and in developing quality systems for houses. method and/or criteria. NOTE 1 Annex A includes background information on this part of ISO 15928, guidance on its use and suggestions on good practice. NOTE 2 Details on references referred to in Notes are provided on Bibliography. NOTE 3 Structural safety, serviceability and other attributes are covered in other parts of ISO 15928.
Houses - Description of performance - Part 3: Structural durability
Briefing for design and construction. Code of practice for facilities management (Buildings infrastructure)
Designing for material efficiency in building projects. Code of Practice for concept and developed design
Rural Residential Energy Saving Design Standards
Environmental performance of buildings. Carbon metric of a building. Use stage
On-site inspection standard for civil building energy saving
This European Standard specifies the general safety requirements applicable to the calculations for cableway installations designed to carry persons. This document is applicable to the various types of cableway installations and takes into account their environment. It contains: general requirements for calculations and their presentation; general requirements relating to the actions that shall be taken into account in the calculation of components as a basis for the requirements of the standards EN 13223, EN 13107, EN 12927 (all parts) and EN 1908; requirements relating to verification of ropes by calculation; requirements relating to the determination of the drive power; requirements for the actions of the ropes and carriers on the support structures and for the deformations of these support structures. It does not apply to installations for the transportation of goods nor to lifts.
Safety requirements for cableway installations designed to carry persons - Calculations
This European Standard classifies roof drains and floor gullies without trap for use inside buildings, gives guidance for places of installation and specifies requirements for the construction, design, performance and marking as well as test methods of factory made roof drains and floor gullies without trap (further: floor gullies) for buildings, irrespective of the material for use in drainage systems. Although normally used to convey rainwater and wastewater, these roof drains and floor gullies without trap may convey other wastewater provided there is no risk of damage to components or of injury to health. This European Standard does not apply to trapped floor gullies with a depth of water seal of at least 50 mm as specified in EN 1253-1.
Gullies for buildings - Part 2: Roof drains and floor gullies without trap
This European Standard classifies floor gullies for use inside buildings, gives guidance for places of installation and specifies requirements for the construction, design, performance and marking of factory made gullies for buildings, irrespective of the material, for use in drainage systems requiring a trap with a depth of water seal of at least 50 mm (further: floor gullies). Although normally used to convey domestic wastewater, these floor gullies may convey other wastewater, e. g. industrial wastewater, provided there is no risk of damage to components or of injury to health. This European Standard does not apply to:- linear drainage channels as specified in EN 1433; - gully tops and manhole tops which are specified in EN 124; - roof drains and floor gullies without trap as specified in EN 1253-2.
Gullies for buildings - Part 1: Trapped floor gullies with a depth water seal of at least 50 mm
This European Standard specifies the general regulations for safety requirements for cableway installations designed to carry persons. Supplementary safety requirements for reversible bi-cable aerial ropeways without carrier truck brakes are established in EN 12929-2. This Part of the EN 12929 defines general technical characteristics and prescribes design principles and general safety requirements. This Part of the EN 12929 does not deal with details of operation and maintenance, calculations and detailed requirements for the manufacture of components. This Part of the EN 12929 includes requirements relating to the prevention of accidents and the protection of workers irrespective of the application of national regulations. National regulations of a building or federal/state nature or which serve to protect particular groups of people remain unaffected. It may not always be possible for all types of cableway installation to transport all particular groups of people (e. g. persons with restricted mobility). The objective should be, however, for a cableway installation to enable the transportation of the largest possible passenger population. This standard does not apply to cableway installations for the transportation of goods or to lifts.
Safety requirements for cableway installations designed to carry persons - General requirements - Part 1: Requirements for all installations
This European Standard specifies additional safety requirements for bicable reversible aerial ropeways without carrier truck brakes. This document is applicable to the various types of cableway installations and takes into account their environment. This Part of the EN 12929 contains: additional requirements relating to the integrity of the haul rope loop; additional requirements intended to prevent specific operational incidents; requirements concerning the attachment of the carriers to the haul rope. This European Standard does not apply to cableway installations for transportation of goods nor to lifts.
Safety requirements for cableway installations designed to carry persons - General requirements - Part 2: Additional requirements for reversible bicable aerial ropeways without carrier truck brakes
Environment design systems of new buildings. Energy efficiency assessment in the design
Technical Specifications for Lightning Protection of Cultural Heritage Buildings Open Section of the Great Wall
Sustainability of construction works - Assessment of social performance of buildings - Calculation methodology; German version EN 16309:2014+A1:2014
本规程适用于建筑工程施工现场及相关区域标志的设置、维护和管理。
Technical specification for signs layout of construction site
Buildings and constructed assets. Service life planning. Terminology
Energy Performance of Buildings. Basic Principles for the set of EPB standards
Energy Performance of Buildings. Detailed Technical Rules for the set of EPB-standards
Sustainability in buildings and civil engineering works. Guidelines on the application of the general principles in ISO 15392
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号