K60 电气设备与器具综合 标准查询与下载



共找到 331 条与 电气设备与器具综合 相关的标准,共 23

Communication Profile Family 6 (commonly known as INTERBUS®1) defines communication profiles based on IEC 61158-2 Type 8, IEC 61158-3-8, IEC 61158-4-8, IEC 61158-5-8, and IEC 61158-6-8. The basic profiles CP 6/1 (INTERBUS) and CP 6/3 (INTERBUS minimal subset) are defined in IEC 61784-1. This part of IEC 62453 provides information for integrating the INTERBUS® technology into the FDT standard (IEC 62453-2). This part of the IEC 62453 specifies communication and other services. This standard neither contains the FDT specification nor modifies it.

Field device tool (FDT) interface specification - Communication profile integration - IEC 61784 CPF 6

ICS
25.040.40;35.100.05;35.110
CCS
K60
发布
2010-01-31
实施
2010-01-31

Communication Profile Family 2 (commonly known as CIP™1) defines communication profiles based on IEC 61158-2 Type 2, IEC 61158-3-2, IEC 61158-4-2, IEC 61158-5-2, IEC 61158-6-2, and IEC 62026-3. The basic profiles CP 2/1 (ControlNet™2), CP 2/2 (EtherNet/IP™3), and CP 2/3 (DeviceNet™1) are defined in IEC 61784-1 and IEC 61784-2. An additional communication profile (CompoNet™1), also based on CIP™, is defined in [14]. This part of IEC 62453 provides information for integrating the CIP™ technology into the FDT interface specification (IEC 62453-2). This part of IEC 62453 specifies communication and other services. This specification neither contains the FDT specification nor modifies it.

Field device tool (FDT) interface specification - Communication profile integration - IEC 61784 CPF 2

ICS
25.040.40;35.100.05;35.110
CCS
K60
发布
2010-01-31
实施
2010-01-31

Communication Profile Family 1 (commonly known as FOUNDATION™ Fieldbus1) defines communication profiles based on IEC 61158-2, Type 1, IEC 61158-3-1, IEC 61158-4-1, IEC 61158-5-5, IEC 61158-5-9, IEC 61158-6-5, and IEC 61158-6-9. The basic profiles CP 1/1 (FF H1) and CP 1/2 (FF HSE) are defined in IEC 61784-1. This part of IEC 62453 provides information for integrating the FOUNDATION™ Fieldbus (FF) protocol into the FDT standard (IEC 62453-2). The standard describes communication definitions, protocol specific extensions and the means for block (e.g. transducer, resource or function blocks) representation. The new protocol specific definitions are based on FF-specifications for H1 and HSE protocols. Furthermore, the definitions contain information that is needed by systems to configure FF devices. The scope is limited to FOUNDATION™ Fieldbus device and system specific definitions.

Field device tool (FDT) interface specification - Communication profile integration - IEC 61784 CPF 1

ICS
25.040.40;35.100.05;35.110
CCS
K60
发布
2010-01-31
实施
2010-01-31

Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test

ICS
13.260;17.220.20
CCS
K60
发布
2010
实施

Applies to the application of electrical, electronic and programmable electronic equipment and systems to machines not portable by hand while working, including a group of machines working together in a co-ordinated manner.

Safety of machinery - Electrical equipment of machines Part 1: General requirements

ICS
29.020
CCS
K60
发布
2009-10-09
实施

IEC 62453-303-2, Ed 1: Field device tool (FDT) interface specification - Part 303-2: Communication profile integration - IEC 61784 CP 3/4, CP 3/5 and CP 3/6

ICS
25.040.40;35.100.05;35.110;35.160;35.240.50
CCS
K60
发布
2009-06
实施
2016-06-24

This part of IEC 62453 presents an overview and guidance for the IEC 62453 series. It • explains the structure and content of the IEC 62453 series (see Clause 5); • provides explanations of some aspects of the IEC 62453 series that are common to many of the parts of the series; • describes the relationship to some other standards.

Field device tool (FDT) interface specification - Part 1: Overview and guidance

ICS
25.040.40;35.100.05;35.110;35.160;35.240.50
CCS
K60
发布
2009-06
实施
2016-12-20

Field device tool (FDT) interface specification - Part 302: Communication profile integration - IEC 61784 CPF 2

ICS
25.040.40;35.100.05;35.110;35.160;35.240.50
CCS
K60
发布
2009-06
实施
2016-06-16

Interpretation Section 1. Introduction to the National Electrical Safety Code Rule 013B3 Application, Existing installations (2007 Edition, page 2) (26 March 2009) IR548

Interpretation Section 1. Introduction to the National Electrical Safety Code Rule 013B3 Application, Existing installations (2007 Edition, page 2) (26 March 2009) IR548

ICS
CCS
K60
发布
2009
实施

This Standard— (a) defines a set of operational instructions that will meet the requirements of Remote Agents wishing to control the energy consumption of airconditioners; and (b) establishes a consistent approach to the configuration of interfaces between Demand Response Enabling Devices (DREDs) and airconditioners. This will provide assistance to manufacturers who wish to supply airconditioners preconfigured for connection to DREDs.

Demand response capabilities and supporting technologies for electrical products

ICS
CCS
K60
发布
2008-12-09
实施

Application integration at electric utilities - System interfaces for distribution management - Part 4: Interfaces for records and asset management (IEC 61968-4:2007); German version EN 61968-4:2007, text in English, Corrigendum to DIN EN 61968-4:2007-12

ICS
35.200
CCS
K60
发布
2008-08
实施

110.1 GENERAL The Regulations apply to the design, erection and verification of electrical installations such as those of: (i) residential premises (ii) commercial premises (iii) public premises (iv) industrial premises (v) agricultural and horticultural premises (vi) prefabricated buildings (vii) caravans, caravan parks and similar sites (viii) construction sites, exhibitions, shows, fairgrounds and other installations for temporary purposes including professional stage and broadcast applications (ix) marinas (x) external lighting and similar installations (xl) mobile or transportable units (xii) photovoltaic systems (xiii) low voltage generating sets (xiv) highway equipment and street furniture. NOTE: "Premises" covers the land and all facilities including buildings belonging to it. The Regulations include requirements tbr: (xv) circuits supplied at nominal voltages up to and including 1000 V a.c. or 1500 V d.c. For a.c., the preferred frequencies which are taken into account in this Standard are 50 Hz, 60 Hz and 400 Hz. The use of other frequencies for special purposes is not excluded (xvi) circuits, other than the internal wiring of equipment, operating at voltages exceeding 1000 V and derived from an installation having a voltage not exceeding 1000 V a.c., e.g. discharge lighting, electrostatic precipitators (xvii) wiring systems and cables not specifically covered by the standards for appliances (xviii) all consumer installations external to buildings (xix) fixed wiring for inlbrmation and communication technology, signalling, control and the like (excluding internal wiring o1' equipment) (xx) additions and alterations to installations and also parts of the existing installation affected by an addition or alteration. The Regulations are intended to be applied to electrical installations generally but, in certain cases, they may need to be supplemented by the requirements or recommendations of other British Standards or by the requirements of the person ordering the work. Such cases include the following: (xxi) Electric signs and high voltage luminous discharge tube installations - BS 559 and BS EN 50107 (xxii) Emergency lighting- BS 5266 (xxiii) Electrical equipment tbr explosive gas atmospheres - BS EN 60079 (xxiv) Electrical equipment tbr use in the presence of combustible dust - BS EN 50281 and BS EN 61241 (xxv) Fire detection and alarm systems in buildings - BS 5839 (xxvi) Telecommunications systems - BS 6701 (xxvii) Electric surface heating systems - BS 6351 (xxviii) Electrical installations for open-cast mines and quarries - BS 6907. (xxix) Design and installation of temporary distribution systems delivering a.c. electrical supplies for lighting, technical services and other entertainment related purposes - BS 7909.

Requirements for electrical installations - IEE Wiring Regulations - Seventeenth edition

ICS
29.020;91.140.50
CCS
K60
发布
2008-07-01
实施
2008-07-01

This is Corrigendum 2 of Safety of machinery - Electro-sensitive protective equipment - Part 1: General requirements and tests and Amendment 1 (2007);

Safety of machinery - Electro-sensitive protective equipment - Part 1: General requirements and tests and Amendment 1 (2007); Corrigendum 2

ICS
13.110
CCS
K60
发布
2008-07
实施
2012-04-11

This International Standard deals with transformations from original quantities into modal quantities for the widely used three-phase a.c. systems in the field of electric power engineering. The examination of operating conditions and transient phenomena in three-phase a.c. systems becomes more difficult by the resistive, inductive or capacitive coupling between the phase elements and line conductors. Calculation and description of these phenomena in three-phase a.c. systems are easier if the quantities of the coupled phase elements and line conductors are transformed into modal quantities. The calculation becomes very easy if the transformation leads to decoupled modal systems. The original impedance and admittance matrices are transformed to modal impedance and admittance matrices. In the case of decoupling of the modal quantities, the modal impedance and admittance matrices become diagonal matrices.

Electric power engineering - Modal components in three-phase a.c. systems - Quantities and transformations

ICS
01.060;17.220.01;29.020
CCS
K60
发布
2008-07
实施
2008-07-25

Operation of electrical installations - Part 100: General requirements - Amendment A1: Periodic verification; German implementation of clause 62 of HD 60364-6:2007

ICS
29.240.01
CCS
K60
发布
2008-06
实施
2008-06-01

Operation of electrical installations - Part 112: Particular requirements for experiments with electrical energy in lecture rooms

ICS
03.180;29.020
CCS
K60
发布
2008-06
实施
2008-06-01

Safety in electroheat installations - Specifications for safety in plasma installations

ICS
25.180.10
CCS
K60
发布
2008-04-30
实施
2008-04-30

IEEE Standards Interpretation for IEEE Std 421.5™ -2005 IEEE Recommended Practice for Excitation System Models for Power System Stability Studies

IEEE Standards Interpretation for IEEE Std 421.5™ -2005 IEEE Recommended Practice for Excitation System Models for Power System Stability Studies

ICS
CCS
K60
发布
2008-04
实施

1.1.1 Object This Code covers the maintenance of electrical equipment for voltages up to and including 22 kV to enhance safe and proper operation of electrical installations with reduced risk of breakdown and the consequent interruption of supply. It represents a standard of good practice and therefore takes the form of recommendations for the maintenance of electrical equipment. It provides information on an organised system of routine maintenance keeping electrical equipment, both indoor and outdoor, and its associated apparatus in good working order. Attention is also drawn to the precautions taken in order to maximise the safety of personnel while maintenance work is in progress. Special maintenance requirements relating to explosion-proof electrical equipment are excluded from this Code. This Code also does not apply to systems for transmission and distribution of electricity to consumer's electrical installations. 1.1.2 Statutory requirements The following government regulations have relevance: 1.1.2.1 Workplace Safety and Health Act - Ministry of Manpower For electrical installations falling within the meaning of the Workplace Safety and Health Act (2006) and amendments made thereafter shall be referred to. 1.1.2.2 The Electricity Act (Cap. 89A), Electricity (Electrical Installations) Regulations 2002 and the Electricity (Electrical Workers) Regulations 2002 - Energy Market Authority The Acts and regulations shall apply to all electrical installations. Under Section 82 of the Electricity Act, it is clearly stated that no person shall perform any electrical work or hold himself out as a licensed electrical worker, etc, unless he has a valid electrical worker licence issued under the said Act. There are three classes of electrical workers licences, namely: a) the electrician licence; b) the electrical technician licence; and c) the electrical engineer licence. The authority conferred upon and the responsibilities of the three classes of licensed electrical workers are spelt out in the Electricity (Electrical Workers) Regulations 2002.

Code of Practice for Maintenance of electrical equipment of electrical installations

ICS
29.020
CCS
K60
发布
2008-03-12
实施

SAFETY OF MACHINERY – ELECTRO-SENSITIVE PROTECTIVE EQUIPMENT – Part 3: Particular requirements for Active Opto-electronic Protective Devices responsive to Diffuse Reflection (AOPDDR) Replacement: This part of IEC 61496 specifies additional requirements for the design, construction and testing of non-contact electro-sensitive protective equipment (ESPE) designed specifically to detect persons as part of a safety related system, employing active opto-electronic protective devices responsive to diffuse reflection (AOPDDRs) for the sensing function. Special attention is directed to requirements which ensure that an appropriate safety-related performance is achieved. An ESPE may include optional safety-related functions, the requirements for which are given both in Annex A of this part and in Annex A of IEC 61496-1. This part does not specify the dimensions or configurations of the detection zone and its disposition in relation to hazardous parts for any particular application, nor what constitutes a hazardous state of any machine. It is restricted to the functioning of the ESPE and how it interfaces with the machine. AOPDDRs are devices that have a detection zone specified in two dimensions wherein radiation in the near infrared range is emitted by a transmitter element(s). When the emitted radiation impinges on an object (for example, a person or part of a person), a portion of the emitted radiation is reflected to a receiving element(s) by diffuse reflection whereby the presence of the object can be detected. Excluded from this part are AOPDDRs employing radiation of wavelength outside the range 820 nm to 946 nm, and those employing radiation other than that generated by the AOPDDR itself. For sensing devices that employ radiation of wavelengths outside this range, this part may be used as a guide. This part is relevant for AOPDDRs having a stated detection capability in the range from 30 mm to 200 mm. AOPDDRs intended for use as trip device using wholebody detection with normal approach to the detection zone and having a stated detection capability not exceeding 200 mm shall meet the requirements of Clause A.12. AOPDDRs intended for a direction of approach normal to the detection zone and having a stated detection capability in the range from 30 mm to 70 mm shall meet the requirements of Clause A.13. This part may be relevant to applications other than those for the protection of persons, for example, for the protection of machinery or products from mechanical damage. In those applications, different requirements may be necessary, for example when the materials that have to be recognized by the sensing function have different properties from those of persons and their clothing. This part does not deal with electromagnetic compatibility (EMC) emission requirements. Opto-electronic devices that perform only one-dimensional spot-like distance measurements, for example, proximity switches, are not covered by this part.

Safety of machinery - Electro-sensitive protective equipment - Part 3: Particular requirements for active opto-electronic protective devices responsive to diffuse reflection (AOPDDR)

ICS
13.100;31.260
CCS
K60
发布
2008-02
实施
2018-12-11



Copyright ©2007-2022 ANTPEDIA, All Rights Reserved