C81 火警监视、报警与消防调度系统 标准查询与下载



共找到 476 条与 火警监视、报警与消防调度系统 相关的标准,共 32

Delete the contents of the Scope and replace with the following text: This European Standard specifies requirements, methods of test and performance criteria for power supply equipment of fire detection and fire alarm systems installed in buildings. This includes component L of Figure 1 of EN 54-1:1996 and power supply equipment that supplies power directly to components other than the control and indicating equipment, unless otherwise specified in other Parts of EN 54.

Fire detection and fire alarm systems - Part 4: Power supply equipment; English version of DIN EN 54-4/A2:2007-01

ICS
13.220.20
CCS
C81
发布
2007-01
实施

1.1 These requirements cover electrically operated smoke detector monitors intended to be used in ordinary indoor locations in accordance with the National Electrical Code, NFPA 70; the Life Safety Code, NFPA 101; and Chapter 2 of the National Fire Alarm Code, NFPA 72. 1.2 As covered by these requirements, a smoke detector monitor is a unit that provides for the connection and supervision of initiating circuits which are, in turn, to be connected to smoke detectors. The smoke detectors may be single station or multiple station and are installed within individual living units of multifamily residences or hotel or motel rooms. The monitor provides alarm or trouble indications at an attended central monitoring location as a supplement to the signal indication provided at the location of the smoke detector. These units are not intended for use as fire protective signaling control units. 1.3 In addition to smoke detector monitoring, a monitor covered by these requirements may provide for manual activation of alarm signals within the individual living units (whether integral with the smoke detectors or not) on either an individual or zone basis. 1.4 An installation wiring diagram attached to the monitor, or referenced in the markings on the monitor, indicates the devices and circuits acceptable for connection to it in the field. 1.5 These requirements do not cover automatic fire detectors or alerting devices not provided as part of the monitor, nor do they cover units intended for connection to smoke detectors that: a) Do not have integral sounding devices or b) Are installed in common areas of multifamily dwellings. 1.6 A product that contains features, characteristics, components, materials, or systems new or different from those covered by the requirements in this Standard, and that involves a risk of fire, electric shock, or injury to persons shall be evaluated using the appropriate additional component and end-product requirements to determine that the level of safety as originally anticipated by the intent of this Standard is maintained. A product whose features, characteristics, components, materials, or systems conflict with specific requirements or provisions of this Standard shall not be judged to comply with this Standard. Where appropriate, revision of requirements shall be proposed and adopted in conformance with the methods employed for development, revision, and implementation of this Standard.

Smoke Detector Monitors and Accessories for Individual Living Units of Multifamily Residences and Hotel/Motel Rooms

ICS
13.220.20
CCS
C81
发布
2006-12-29
实施

This standard shall specify minimum design, performance, and certification requirements and test methods for all Personal Alert Safety Systems (PASS) to be used by fire fighters and other emergency services personnel who engage in rescue, fire fighting, and other hazardous duties.This standard shall apply to the design, manufacturing, and certification of all new PASS including, but not limited to, Stand-Alone PASS and SCBA-Integrated PASS. This standard shall not apply to any PASS manufactured to previous editions of this standard. The requirements of this standard shall not apply to accessories that might be attached to PASS unless specifically addressed herein.Nothing herein is intended to restrict any jurisdiction or manufacturer from exceeding these minimum requirements.

Standard on Personal Alert Safety Systems (PASS)

ICS
13.220.10;13.320
CCS
C81
发布
2006-12-20
实施

BS 5839-1 and BS 5839-6 Standards and Guides - Fire detection and fire alarm systems for buildings

ICS
13.220.20;13.320
CCS
C81
发布
2006-11-30
实施
2006-11-30

Fire detection and fire alarm systems - Part 4 : power supply equipment.

ICS
13.220.20
CCS
C81
发布
2006-11-01
实施
2006-11-05

This Clause of EN 50194 is replaced by: This European Standard specifies test methods and performance requirements for electrical apparatus for the detection of combustible gases designed for continuous operation in a fixed installation in recreational vehicles and similar premises. NOTE 1 For caravan holiday homes EN 50194 applies. This standard specifies apparatus designed to operate in the event of an escape of liquefied petroleum gas (LPG) and/or petrol (gasoline) vapour and to provide a visual and audible alarm and an executive action in the form of an output signal that can actuate directly or indirectly a shut-off device and/or other ancillary device (Type A of EN 50194). The standard excludes apparatus for the detection of toxic gases such as carbon monoxide (see EN 50291). Apparatus complying with this standard is not considered suitable for industrial or commercial installations for which EN 61779-1 and EN 61779-4 apply.

Electrical apparatus for the detection of combustible gases in domestic premises - Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises - Additional test methods and performance requirements

ICS
13.320
CCS
C81
发布
2006-10-31
实施
2006-10-31

These requirements cover smoke detectors intended to be employed in indoor locations in accordance with the National Fire Alarm Code, NFPA 72. These requirements also cover mechanical guards used to provide physical protection to installed smoke detectors. A smoke detector, as covered by these requirements, consists of an assembly of electrical components coupled with a sensing means inside of a chamber, or by separate components, to detect smoke. The detector includes provision for the connection to a source of power, signaling, and remote control circuits. A heat detector, or audible signaling appliance, or both, are not prohibited from being incorporated as part of the smoke detector assembly. These requirements cover the following types of detectors: a) Detectors intended for open area protection and for connection to a compatible power supply or control unit for operation as part of a fire alarm system. b) Detectors intended solely for control of releasing devices such as electromagnetic door holders, fire dampers or smoke dampers. c) Detectors intended for both the applications described in (a) and (b) above. This standard does not cover the following: a) Control units to which the detectors are intended to be connected that are covered by the Standard for Control Units for Fire-Protective Signaling Systems, UL 864. b) Self-contained single and multiple station smoke detectors, not intended for connection to a system control unit, that are covered by the Standard for Single and Multiple Station Smoke Alarms, UL 217. c) A heat detector incorporated as a part of a smoke detector assembly, and covered by the Standard for Heat Detectors for Fire Protective Signaling Systems, UL 521; except for the requirements of the Fire Test (Heat Detector). d) Fire tests for smoke detectors integral with combination door closers and holders that are covered by the Standard for Door Closers-Holders, With or Without Integral Smoke Detectors, UL 228. e) Commercial-residential detectors not intended for connection to a system control unit that are covered by the Standard for Smoke Detector Monitors and Accessories for Individual Living Units of Multifamily Residences and Hotel/Motel Rooms, UL 1730. These requirements also cover all remote accessories that are intended to be connected to a smoke detector. A product that contains features, characteristics, components, materials, or systems new or different from those covered by the requirements in this standard, and that involves a risk of fire, electric shock, or injury to persons shall be evaluated using the appropriate additional component and end-product requirements as determined essential to maintain the intended level of safety as originally anticipated by the intent of this standard. A product whose features, characteristics, components, materials, or systems conflict with specific provisions of this standard cannot be judged to comply with this standard. Where identified as appropriate, revision of requirements shall be proposed and adopted in conformance with the methods employed for development, revision, and implementation of this standard.

Smoke detectors for fire alarm signaling systems

ICS
13.220.20
CCS
C81
发布
2006-09-08
实施

This European Standard specifies requirements, test methods and performance criteria for point smoke detectors that operate using scattered light, transmitted light or ionization, for use in fire detection and fire alarm systems for buildings (see EN 54-1:1996). For other types of smoke detector, or smoke detectors working on different principles, this standard should only be used for guidance. Smoke detectors with special characteristics and developed for specific risks are not covered by this standard. Annex N that gives additional requirements for detectors with more than one smoke sensor.#,,#

Fire detection and fire alarm systems - Part 7: Smoke detectors - Point detectors using scattered light, transmitted light or ionization (includes Amendments A1:2002+A2:2006) English version of DIN EN 54-7:2006-09

ICS
13.220.20
CCS
C81
发布
2006-09
实施
2006-09-01

These requirements cover electrically operated single and multiple station smoke alarms intended for open area protection in indoor locations of residential units in accordance with the National Fire Alarm Code, NFPA 72, smoke alarms intended for use in recreational vehicles in accordance with the Standard for Recreational Vehicles, NFPA 501C, and portable smoke alarms used as "travel" alarms. A single station smoke alarm, as defined by these requirements, is a self-contained fire alarm device that consists of an assembly of electrical components including a smoke chamber, alarm sounding appliance, and provision for connection to a power supply source, either by splice leads or a cord and plug arrangement or containing integral batteries. Possible accessories include a supplemental heat detector, terminals for connection to a remote audible signaling appliance or accessory, and an integral transmitter to energize a remote audible signaling appliance. Multiple station units are single station smoke alarms that are either interconnected for common alarm annunciation or connected to remote thermostats. These requirements, where applicable, also cover all remote accessories that are to be connected to or are intended to be used with a single or multiple station smoke alarm. See 33.2.1. This standard does not cover the following: a) Smoke detectors of the non-self-contained type that are intended for connection to a household or industrial system control unit. These are included in the Standard for Smoke Detectors for Fire Protective Signaling Systems, UL 268. b) Mechanically operated single and multiple station fire alarm devices that are specified in the Standard for Single and Multiple Station Heat Detectors, UL 539. c) Heat detectors [except for the requirements in the Fire Test (Heat Detector), Section 73] incorporated as part of a single station smoke alarm assembly whose requirements are covered in the Standard for Heat Detectors for Fire Protective Signaling Systems, UL 521.

UL Standard for Safety Single and Multiple Station Smoke Alarms Sixth Edition; Reprint with Revisions Through and Including May 22, 2007

ICS
13.220.20
CCS
C81
发布
2006-08-25
实施

This Standard specifies minimum requirements and test methods for Smoke alarms for residential or similar application. Smoke alarms for the purpose of this Standard can be used as self-contained smoke alarms or in systems, but shall not be used in fire detection and fire alarm systems in accordance with DIN 14675 and DIN VDE 0833-3 (VDE 0833-2) or as substitute for a fire detection and fire alarm system in accordance with special construction rules.#,,#

Smoke alarm devices for use in residential buildings, apartments and rooms with similar purposes - Installation, use and maintenance

ICS
13.220.20
CCS
C81
发布
2006-08
实施

Fire detection and fire alarm systems - Part 3: Fire alarm devices - Sounders English version of DIN EN 54-3:2006-08

ICS
13.220.20
CCS
C81
发布
2006-08
实施
2006-08-01

This European Standard specifies requirements, test methods and performance criteria against which the effectiveness and reliability of routing equipment capable of transmitting fire alarm and/or fault warning signals for use with fire detection and fire alarm systems installed in buildings can be assessed (see EN 54-1). The routing equipment is designed to allow the system to function in accordance with the requirements of this European Standard. It also provides for the evaluation of conformity of the equipment to the requirements of this standard. The releationship with the EU Construction Doirective ist given in Annex ZA.#,,#

Fire detection and fire alarm systems - Part 21: Alarm transmission and fault warning routing equipment; German version EN 54-21:2006

ICS
13.220.20
CCS
C81
发布
2006-08
实施
2006-08-01

1.1 These requirements cover fire dampers that are intended for use where air ducts penetrate or terminate at openings in walls or partitions; in air transfer openings in partitions; and where air ducts extend through floors as specified in the Standard for Installation of Air-Conditioning and Ventilating Systems, NFPA 90A. Fire dampers are intended for installation in accordance with codes such as the BOCA National Mechanical Code, SBCCI Standard Mechanical Code, ICBO Uniform Mechanical Code, and the International Mechanical Code. 1.2 Fire dampers are evaluated for use as either: a) Fire Dampers for Static Systems - For HVAC systems that are automatically shut down in the event of a fire or for air transfer openings in walls or partitions, b) Fire Dampers for Dynamic Systems - For HVAC systems that are operational in the event of a fire, or c) Combination Fire and Smoke Dampers - For locations in HVAC systems where a fire damper and a smoke damper are required at a single location. 1.3 Under these requirements a fire damper is subjected to a standard fire exposure, controlled to achieve specified temperatures throughout a specified time period, followed by the application of a specified standard hose stream. This exposure by itself is not representative of all fire conditions; conditions vary with changes in

UL Standard for Safety Fire Dampers Seventh Edition

ICS
13.220.20
CCS
C81
发布
2006-07-12
实施

Fire detection and fire alarm systems - Part 3 : fire alarm devices - Sounders.

ICS
13.220.20
CCS
C81
发布
2006-07-01
实施
2006-07-20

This European Standard specifies the requirements, test methods and performance criteria for aspirating smoke detectors for use in fire detection and fire alarm systems installed in buildings. Aspirating smoke detectors developed for the protection of specific risks that incorporate special characteristics (including additional features or enhanced functionality for which this standard does not define a test or assessment method) are not covered by this standard. The performance requirements for any special characteristics are beyond the scope of this standard. NOTE Certain types of detector contain radioactive materials. The national requirements for radiation protection differ from country to country and they are not therefore specified in this standard.

Fire detection and fire alarm systems - Aspirating smoke detectors

ICS
13.220.20
CCS
C81
发布
2006-06-30
实施
2006-06-30

This European Standard specifies requirements, test methods and performance criteria against which the effectiveness and reliability of routing equipment capable of transmitting fire alarm and/or fault warning signals for use with fire detection and fire alarm systems installed in buildings can be assessed (see EN 54- 1). The routing equipment is designed to allow the system to function in accordance with the requirements of this European Standard. It also provides for the evaluation of conformity of the equipment to the requirements of this standard.

Fire detection and fire alarm systems - Alarm transmission and fault warning routing equipment

ICS
13.220.20
CCS
C81
发布
2006-06-30
实施
2006-06-30

This amendement A1 to DIN EN 54-11:2001-10 includes annex ZA with the relationship to the European Construction Directive (89/106/EEC).

Fire detection and fire alarm systems - Part 11: Manual call points; English version of DIN EN 54-11/A1:2006-03

ICS
13.220.20
CCS
C81
发布
2006-03
实施
2006-03-01

This amendement A 1 to DIN EN 54-10:2002-05 includes annex ZA with the relationship with the European Construction Product Directive (89/106/EEC).

Fire detection and fire alarm systems - Part 10: Flame detectors - Point detectors; English version of DIN EN 54-10/A1:2006-03

ICS
13.220.20
CCS
C81
发布
2006-03
实施
2006-03-01

This European Standard specifies requirements, test methods and performance requirements for short circuit isolators which are used as components in fire detection and fire alarm systems in buildings.#,,#

Fire detection and fire alarm systems - Part 17: Short-circuit isolators; English version of DIN EN 54-17:2006-03

ICS
13.220.20
CCS
C81
发布
2006-03
实施
2006-03-01

This European Standard specifies requirements, test methods and performance criteria for input/output devices connected to a transmission path of a fire detection and fire alarm system, used to receive and/or transmit electrical signals to or from the transmission path, necessary for the operation of the fire detection and fire alarm system and/or fire protection system. An input/output device may be a physically separate device or its function may be integrated into another device in which case this European Standard may be used to assess this function. Control and indicating equipment, and ancillary control and indicating equipment (e.g. repeater panels and fire brigade panels) are not covered by this European Standard.

Fire detection and fire alarm systems - Part 18: Input/output devices; English version of DIN EN 54-18:2006-03

ICS
13.220.20
CCS
C81
发布
2006-03
实施
2006-03-01