共找到 472 条与 火警监视、报警与消防调度系统 相关的标准,共 32 页
Fire detection and fire alarm systems - System interconnection
本标准规定了家用燃气报警器及传感器的要求、试验方法、检验规则、标志、包装、运输和贮存。本标准适用于检测燃气泄漏和检测燃气不完全燃烧产生的一氧化碳的家用燃气报警器及传感器。
Household combustible gas alarms and sensor
Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gas
本标准规定了火场通信控制台的术语和定义、技术要求、试验方法、检验规则和标志。 本标准适用于公安消防部队移动通信指挥车安装使用的火场通信控制台。
Fire scene communication console
Fire detection and fire alarm systems - Part 23: Fire alarm devices - Visual alarm devices; German version EN 54-23:2010
Fire detection and fire alarm systems - Part 25: Components using radio transmission paths
This European Standard specifies the requirements, test methods and performance criteria for visual alarm devices in a fixed installation intended to signal a visual warning of a fire between the fire detection and fire alarm system and the occupants of a building (see item C of Figure 1 of EN 54-1:1996). It is intended to cover only those devices which derive their operating power by means of a physical electrical connection to an external source such as a fire alarm system. This European Standard specifies the evaluation of conformity and the marking of the visual alarm devices. This European Standard applies to visual alarm devices that rely on software for their operation and to those that do not. This European Standard applies only to pulsing or flashing visual alarm devices, for example xenon beacons or rotating beacons. Devices giving continuous light output are excluded from this European Standard. This European Standard is not intended to cover visual indicators, for example those on detectors or on the control and indicating equipment.
Fire detection and fire alarm systems - Fire alarm devices - Visual alarm devices
construction ofManagement for fire Equipment in Building
Fire detection and alarm systems - Part 20: Aspirating smoke detectors
This part of ISO 7240 specifies requirements, test methods and performance criteria for loudspeakers intended to broadcast a warning of fire between a fire detection and alarm system and the occupants of a building (see item C4 of ISO 7240-1:2005). This part of ISO 7240 specifies loudspeakers for two types of application environment: type A, generally for indoor use, and type B, generally for outdoor use. This part of ISO 7240 does not cover loudspeakers for special applications, for example loudspeakers for use in hazardous applications, if such applications require additional or other requirements or tests other than those given in this part of ISO 7240. This part of ISO 7240 is not intended to cover addressable loudspeakers or loudspeakers with active components. Audible alarm indicators are covered in the future ISO 7240-3.
Fire detection and fire alarm systems - Part 24: Sound-system loudspeakers
The document specifies the requirements for fire brigade indication panels and gives principles for its conformity testing, marking, installation, inspection, operation and maintenance. The fire brigade indication panels serve to the connection of fire detection and fire alarm systems to the control and indicating equipment according to DIN 14675 which are connected to an automatic fire protection equipment for the automatic call of the fire brigade.
Firefighting and fire protection - Fire-brigade indication panel for fire detection and fire alarm systems
Revision to proposal dated August 14, 2009
Heat Detectors for Fire Protective Signaling Systems
1. Quad-Rated TC, PLTC, FPL and NPLF
Standard for Safety for Cables for Non-Power-Limited Fire-Alarm Circuits
1.1 Scope This document provides criteria for evaluating the protection, construction, and operational features of specific occupancies to develop a pre-incident plan that should be used by responding personnel to manage fires and other emergencies in such occupancies using the available resources. 1.1.1 Chapter 1 through Chapter 10 of this document provide general information, philosophies, and principles that might or might not be applicable to all occupancies. 1.1.2* The authority having jurisdiction should determine the level of planning appropriate for the jurisdiction and the property being pre-planned. 1.1.3 Chapter 11 through Chapter 20 provide information addressing special or unique characteristics of specific occupancy classifications.
Standard for Pre-Incident Planning
This standard describes practices for installing, testing, and maintaining fire alarm systems. These job practices represent a minimum level of quality for fire alarm system installations.
Standard for Fire Alarm System Job Practices
Specifies the requirements, test methods and performance criteria for aspirating smoke detectors for use in fire detection and fire alarm systems installed in buildings.
Fire detection and fire alarm systems Part 20: Aspirating smoke detectors
Fire detection and alarm systems - Part 18: Input/output devices
Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gas
本标准规定了消防控制室图形显示装置软件(以下简称软件)的一般要求、显示和操作、信息记录、信息传输和维护的要求。 本标准适用于消防控制室安装的图形显示装置的软件产品。
General technical requirement of the software for graph indicator in fire control center
Alarm systems for fire, intrusion and hold-up - Part 1: General requirements
Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号