GB/T 14048.6-2016
Low-voltage switchgear and controlgear—Part 4-2: Contactors and motor-starters—AC semiconductor motor controllers and starters (including soft-starters) (English Version)

GB/T 14048.6-2016
Standard No.
GB/T 14048.6-2016
Language
Chinese, Available in English version
Release Date
2016
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB/T 14048.6-2016
Replace
GB 14048.6-2008
Scope
This part of GB/T 14048 applies to semiconductor controllers and starters for AC motors intended to be connected to circuits with a rated voltage not exceeding AC 1000V, which may have a series mechanical switching device. This standard specifies the characteristics of semiconductor controllers and starters for a.c. motors with or without bypass switching devices when used. Semiconductor controllers and starters for AC motors covered by this standard are generally not intended for breaking short-circuit currents. Therefore, appropriate short-circuit protective devices should be used (see 8.2. This appendix specifies the test methods for verifying the performance of the overload protective devices in the starter when the starter is used in conjunction with the SCPD. C.2 Overview and definitions K.1.1 General requirements The appendix specifies the extended functions of electronic overload relays that are not directly related to overload protection. The functions of overload relays not specified in this part shall meet the requirements of relevant standards (such as IEC60255 series, IEC60947 5 series) that include this function. This appendix only Suitable for electronic overload relays used in AC circuits. K.1.2 Residual current protection

GB/T 14048.6-2016 Referenced Document

  • GB 13539.1-2015 Low-voltage fuses.Part 1:General requirements
  • GB/T 11021-2014 Electrical insulation.Thermal evaluation and designation
  • GB/T 14048.6-2016 Low-voltage switchgear and controlgear—Part 4-2: Contactors and motor-starters—AC semiconductor motor controllers and starters (including soft-starters)
  • GB/T 2828.1-2012 Inspection procedure by count sampling part 1: Lot by lot inspection sampling plan retrieved by acceptance quality limit (AQL)
  • IEC 60034-1:2010 Rotating electrical machines - Part 1: Rating and performance
  • IEC 60947-1:2007 Low-voltage switchgear and controlgear - Part 1: General rules

GB/T 14048.6-2016 history

  • 2016 GB/T 14048.6-2016 Low-voltage switchgear and controlgear—Part 4-2: Contactors and motor-starters—AC semiconductor motor controllers and starters (including soft-starters)
  • 2008 GB 14048.6-2008 Low-voltage switchgear and controlgear.Part 4-2:Contactors and motor-starters.AC semiconductor motor controllers and starters(including soft-starter)
  • 1998 GB 14048.6-1998 Low-voltage switchgear and controlgear. Contactors and motor-starters. Section 2: AC semiconductor motor controllers and starters

GB/T 14048.6-2016 Low-voltage switchgear and controlgear—Part 4-2: Contactors and motor-starters—AC semiconductor motor controllers and starters (including soft-starters) has been changed from GB 14048.6-2008 Low-voltage switchgear and controlgear.Part 4-2:Contactors and motor-starters.AC semiconductor motor controllers and starters(including soft-starter).


GB/T 14048.6-2016 -All Parts

GB/T 14048.1-2023 Low voltage switchgear and controlgear Part 1: General principles GB/T 14048.10-2016 Low-voltage switchgear and controlgear—Part 5-2: Control circuit devices and switching elements—Proximity switches GB/T 14048.11-2016 Low-voltage switchgear and control gear.Part 6-1:Multiple function equipment.Transfer switching equipment GB/T 14048.12-2016 Low-voltage switchgear and controlgear Part 4-3: Contactors and motor starters for AC semiconductor controllers and contactors for non-motor loads GB/T 14048.13-2017 Low-voltage switchgear and controlgear—Part 5-3: Control circuit devices and switching elements—Requirements for proximity devices with defined behaviour under fault conditions (PDDB) GB/T 14048.14-2019 Low-voltage switchgear and controlgear—Part 5-5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function GB/T 14048.15-2006 Low-voltage switchgear and controlgear Part 5-3: Control circuit devices and switching elements DC interface for proximity sensors and switching amplifiers (NAMUR) GB/T 14048.16-2016 Low-voltage switchgear and controlgear - Part 8: Built-in thermal protection (PTC) control units for rotating electrical machines GB/T 14048.17-2008 Low-voltage switchgear and controlgear.Part 5-4:Control circuit devices and switching elements.Method of assessing the performance of low-formance of low-energy contacts.Special tests GB/T 14048.18-2016 Low-voltage switchgear and controlgear.Part 7-3:Ancillary equipment.Safety requirements for fuse terminal blocks GB/T 14048.19-2013 Low-voltage switchgear and controlgear.Part 5-7: Control circuit devices and switching elements.Requirements for proximity devices with analogue output GB/T 14048.2-2020 Low-voltage switchgear and controlgear—Part 2: Circuit-breakers GB/T 14048.20-2013 Low-voltage switchgear and controlgear.Part 5-8:Control circuit devices and switching elements.Three-position enabling switches GB/T 14048.21-2013 Low-voltage switchgear and controlgear.Part 5-9: Control circuit devices and switching elements.Flow rate switches GB/T 14048.22-2022 Low-voltage switchgear and controlgear—Part 7-4: Ancillary equipment—PCB terminal blocks for copper conductors GB/T 14048.23-2022 Low-voltage switchgear and controlgear—Part 9-1: Active arc-fault mitigation systems—Arc quenching devices GB/T 14048.3-2017 Low-voltage switchgear and controlgear—Part3: Switches,disconnectors,switch-disconnectors and fuse-combination units GB/T 14048.4-2020 Low-voltage switchgear and controlgear—Part 4-1: Contactors and motor-starters—Electromechanical contactors and motor-starters (Including motor protector) GB/T 14048.5-2017 Low-voltage switchgear and controlgear—Part 5-1: Control circuit devices and switching element—Electromechanical control circuit devices GB/T 14048.6-2016 Low-voltage switchgear and controlgear—Part 4-2: Contactors and motor-starters—AC semiconductor motor controllers and starters (including soft-starters) GB/T 14048.7-2016 Low-voltage switchgear and controlgear.Part 7-1:Ancillary equipment.Terminal blocks for copper conductors GB/T 14048.8-2016 Low-voltage switchgear and controlgear.Part 7-2:Ancillary equipment.Protective conductor terminal blocks for copper conductors GB/T 14048.9-2008 Low-voltage switchgear and controlgear - Section 6-2: Multiple function equipment control and protective switching devices (or equipment) (CPS)