GB/T 14048.7-2016
Low-voltage switchgear and controlgear.Part 7-1:Ancillary equipment.Terminal blocks for copper conductors (English Version)

GB/T 14048.7-2016
Standard No.
GB/T 14048.7-2016
Language
Chinese, Available in English version
Release Date
2016
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB/T 14048.7-2016
Replace
GB/T 14048.7-2006
Scope
This part of GB 14048 specifies the requirements for threaded or non-screwed terminal blocks that are mainly used for industrial or similar purposes and are installed on brackets to provide electrical connections and mechanical connections for copper conductors. This section applies to circuits with a rated voltage AC not exceeding 1 000 V, a frequency up to 1 000 Hz or a DC not exceeding 1 500 V, for connections with a cross-sectional area of 0.2 mm2~300 mm2( AWG24/600 kcmil) Terminal block for round copper conductors with or without special processing. The following products can use this part as a guide: -- Terminal blocks that require special devices on the wires, such as quick-connect terminals or wrap-around connections, etc.; terminal blocks, such as insulation transfer connectors, etc.; -- special types of terminal blocks, such as those with diodes or varistors or similar component holders. When referring to GB 14048.1-2012, the term "clamping member" is used in this part instead of "terminal".

GB/T 14048.7-2016 Referenced Document

  • GB 14048.1-2012 Low-voltage switchgear and controlgear.Part 1:General rules
  • GB/T 5169.5-2008 Fire hazard testing for electric and electronic products.Part 5:Test flames.Needle test method.Apparatus,confirmatory arrangement and guidance
  • ISO 4046-4:2002 Paper, board, pulps and related terms - Vocabulary - Part 4: Paper and board grades and converted products

GB/T 14048.7-2016 history

  • 2016 GB/T 14048.7-2016 Low-voltage switchgear and controlgear.Part 7-1:Ancillary equipment.Terminal blocks for copper conductors
  • 2006 GB/T 14048.7-2006 Low voltage switchgear and controlgear Part 7-1: Ancillary equipment Terminal blocks for copper conductors
  • 1998 GB 14048.7-1998 Low-voltage switchgear and controlgear. Ancillary equipment. Section 1: Terminal blocks for copper conductors

GB/T 14048.7-2016 -All Parts

GB/T 14048.1-2023 Low voltage switchgear and controlgear Part 1: General principles GB/T 14048.10-2016 Low-voltage switchgear and controlgear—Part 5-2: Control circuit devices and switching elements—Proximity switches GB/T 14048.11-2016 Low-voltage switchgear and control gear.Part 6-1:Multiple function equipment.Transfer switching equipment GB/T 14048.12-2016 Low-voltage switchgear and controlgear Part 4-3: Contactors and motor starters for AC semiconductor controllers and contactors for non-motor loads GB/T 14048.13-2017 Low-voltage switchgear and controlgear—Part 5-3: Control circuit devices and switching elements—Requirements for proximity devices with defined behaviour under fault conditions (PDDB) GB/T 14048.14-2019 Low-voltage switchgear and controlgear—Part 5-5: Control circuit devices and switching elements—Electrical emergency stop device with mechanical latching function GB/T 14048.15-2006 Low-voltage switchgear and controlgear Part 5-3: Control circuit devices and switching elements DC interface for proximity sensors and switching amplifiers (NAMUR) GB/T 14048.16-2016 Low-voltage switchgear and controlgear - Part 8: Built-in thermal protection (PTC) control units for rotating electrical machines GB/T 14048.17-2008 Low-voltage switchgear and controlgear.Part 5-4:Control circuit devices and switching elements.Method of assessing the performance of low-formance of low-energy contacts.Special tests GB/T 14048.18-2016 Low-voltage switchgear and controlgear.Part 7-3:Ancillary equipment.Safety requirements for fuse terminal blocks GB/T 14048.19-2013 Low-voltage switchgear and controlgear.Part 5-7: Control circuit devices and switching elements.Requirements for proximity devices with analogue output GB/T 14048.2-2020 Low-voltage switchgear and controlgear—Part 2: Circuit-breakers GB/T 14048.20-2013 Low-voltage switchgear and controlgear.Part 5-8:Control circuit devices and switching elements.Three-position enabling switches GB/T 14048.21-2013 Low-voltage switchgear and controlgear.Part 5-9: Control circuit devices and switching elements.Flow rate switches GB/T 14048.22-2022 Low-voltage switchgear and controlgear—Part 7-4: Ancillary equipment—PCB terminal blocks for copper conductors GB/T 14048.23-2022 Low-voltage switchgear and controlgear—Part 9-1: Active arc-fault mitigation systems—Arc quenching devices GB/T 14048.3-2017 Low-voltage switchgear and controlgear—Part3: Switches,disconnectors,switch-disconnectors and fuse-combination units GB/T 14048.4-2020 Low-voltage switchgear and controlgear—Part 4-1: Contactors and motor-starters—Electromechanical contactors and motor-starters (Including motor protector) GB/T 14048.5-2017 Low-voltage switchgear and controlgear—Part 5-1: Control circuit devices and switching element—Electromechanical control circuit devices GB/T 14048.6-2016 Low-voltage switchgear and controlgear—Part 4-2: Contactors and motor-starters—AC semiconductor motor controllers and starters (including soft-starters) GB/T 14048.7-2016 Low-voltage switchgear and controlgear.Part 7-1:Ancillary equipment.Terminal blocks for copper conductors GB/T 14048.8-2016 Low-voltage switchgear and controlgear.Part 7-2:Ancillary equipment.Protective conductor terminal blocks for copper conductors GB/T 14048.9-2008 Low-voltage switchgear and controlgear - Section 6-2: Multiple function equipment control and protective switching devices (or equipment) (CPS)