GB 3836.17-2007
Electrical apparatus for explosive gas atmosphere Part 17: Construction and use of rooms or buildings protected by pressurization (English Version)

GB 3836.17-2007
Standard No.
GB 3836.17-2007
Language
Chinese, Available in English version
Release Date
2007
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Status
 2020-07
Replace By
GB/T 3836.17-2019
Latest
GB/T 3836.17-2019
Scope
This standard specifies the method of filling a protective gas to make the pressure in a room or building containing electrical equipment that may become a source of ignition and where explosive gases or vapors may appear higher than the external atmospheric pressure to prevent such gases or Measures against the penetration of vapors into the interior of the room. This part specifies the structure, equipment and operating rules of rooms or buildings and their related parts, such as the inlet and outlet pipelines of protective gas, some auxiliary control devices required to generate and maintain overpressure, etc. This section also specifies the test methods used to prove that the facility complies with this section, and the signs set on the room or building. This section applies only to rooms or buildings in which flammable gases or vapours cannot be released (actually or possibly).

GB 3836.17-2007 Referenced Document

  • GB 3836.14-2000 Electrical apparatus for explosive gas atmospheres. Part 14: Classification of hazardous areas

GB 3836.17-2007 history

  • 2019 GB/T 3836.17-2019 Explosive atmospheres—Part 17: Equipment protection by pressurized room “p”and artifically ventilated room “v”
  • 2007 GB 3836.17-2007 Electrical apparatus for explosive gas atmosphere Part 17: Construction and use of rooms or buildings protected by pressurization

GB 3836.17-2007 Electrical apparatus for explosive gas atmosphere Part 17: Construction and use of rooms or buildings protected by pressurization was changed to GB/T 3836.17-2019 Explosive atmospheres—Part 17: Equipment protection by pressurized room “p”and artifically ventilated room “v”.


GB 3836.17-2007 -All Parts

GB 3836.1-2010 Explosive atmospheres.Part 1:Equipment.General requirements GB 3836.10-1991 Electrical apparatus for explosive atmospheres--Hermetically sealed electrical apparatus "h" GB 3836.11-2008 Explosive atmospheres.Part11:Equipment protection by flameproof enclosures"d"method of test for ascertainment of maximum experimental safe gap GB 3836.12-2008 Explosive atmospheres.Part 12:Classification of mixtures of gases or vapours with air according to their maximum experimental safe gaps and minimum igniting current GB 3836.13-2013 Explosive atmospheres.Part 13:Equipment repair, overhaul and reclamation GB 3836.14-2014 Explosive atmospheres.Part 14:Classification of areas.Explosive gas atmosphere GB 3836.15-2000 Electrical apparatus for explosive gas atmospheres. Part 15: Electrical installation in hazardous areas (other than mines) GB 3836.16-2006 Electrical apparatus for explosive gas atmospheres.Part 16:Inspection and maintenance of electrical installation(other than mines) GB 3836.17-2007 Electrical apparatus for explosive gas atmosphere Part 17: Construction and use of rooms or buildings protected by pressurization GB 3836.18-2010 Explosive atmospheres.Part 18:Intrinsically safe system GB 3836.19-2010 Explosive atmospheres.Part 19:Fieldbus intrinsically safe concept (FISCO) GB 3836.2-2010 Explosive atmospheres.Part 2:Equipment protection by flameproof enclosures "d" GB 3836.20-2010 Explosive atmospheres.Part 20:Equipment with equipment protection level(EPL)Ga GB 3836.3-2010 Explosive atmospheres.Part 3:Equipment protection by increased safety "e" GB 3836.4-2010 Explosive atmospheres.Part 4:Equipment protection by intrinsic safety "i" GB 3836.5-2004 Electrical apparatus for explosive gas atmosphere-Part 5:Pressurized enclosures"p" GB 3836.6-2004 Electrical apparatus for explosive gas atmospheres-Part 6:Oil-immersion"o" GB 3836.7-2004 Electrical apparatus for explosive gas atmospheres-Part 7:Power filling"q" GB 3836.8-2014 Explosive atmospheres.Part 8: Equipment protection by type of protection “n” GB 3836.9-2014 Explosive atmospheres.Part 9:Equipment protection by type of protection "m"