GB 3836.5-2004
Electrical apparatus for explosive gas atmosphere-Part 5:Pressurized enclosures"p" (English Version)

GB 3836.5-2004
Standard No.
GB 3836.5-2004
Language
Chinese, Available in English version
Release Date
2004
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Status
 2018-02
Replace By
GB/T 3836.5-2017
Latest
GB/T 3836.5-2021
Replace
GB 3836.5-1987
Scope
This part of GB 3836 specifies the special requirements for the structure and test of positive pressure enclosure type electrical equipment "P" for explosive gas atmospheres. The requirements in this part are supplementary to GB 3836.1. This standard specifies requirements for positive pressure enclosures containing restricted release of flammable substances. This standard does not cover the requirements for positive pressure enclosures containing built-in systems that can release flammable substances: a) air with an oxygen content greater than normal, or b) a mixture of oxygen and inert gases greater than 21%. This standard does not include requirements for positive pressure chambers or analysis chambers.

GB 3836.5-2004 history

  • 2021 GB/T 3836.5-2021 Explosive atmospheres—Part 5:Equipment protection by pressurized enclosure “p”
  • 2017 GB/T 3836.5-2017 Explosive atmospheres—Part 5:Equipment protection by pressurized enclosure “p“
  • 2004 GB 3836.5-2004 Electrical apparatus for explosive gas atmosphere-Part 5:Pressurized enclosures"p"
  • 1987 GB 3836.5-1987 Electrical apparatus for explosive atmospheres--Pressurized electrical apparatus"p"

GB 3836.5-2004 Electrical apparatus for explosive gas atmosphere-Part 5:Pressurized enclosures"p" was changed to GB/T 3836.5-2017 Explosive atmospheres—Part 5:Equipment protection by pressurized enclosure “p“.


GB 3836.5-2004 -All Parts

GB 3836.1-2010 Explosive atmospheres.Part 1:Equipment.General requirements GB 3836.10-1991 Electrical apparatus for explosive atmospheres--Hermetically sealed electrical apparatus "h" GB 3836.11-2008 Explosive atmospheres.Part11:Equipment protection by flameproof enclosures"d"method of test for ascertainment of maximum experimental safe gap GB 3836.12-2008 Explosive atmospheres.Part 12:Classification of mixtures of gases or vapours with air according to their maximum experimental safe gaps and minimum igniting current GB 3836.13-2013 Explosive atmospheres.Part 13:Equipment repair, overhaul and reclamation GB 3836.14-2014 Explosive atmospheres.Part 14:Classification of areas.Explosive gas atmosphere GB 3836.15-2000 Electrical apparatus for explosive gas atmospheres. Part 15: Electrical installation in hazardous areas (other than mines) GB 3836.16-2006 Electrical apparatus for explosive gas atmospheres.Part 16:Inspection and maintenance of electrical installation(other than mines) GB 3836.17-2007 Electrical apparatus for explosive gas atmosphere Part 17: Construction and use of rooms or buildings protected by pressurization GB 3836.18-2010 Explosive atmospheres.Part 18:Intrinsically safe system GB 3836.19-2010 Explosive atmospheres.Part 19:Fieldbus intrinsically safe concept (FISCO) GB 3836.2-2010 Explosive atmospheres.Part 2:Equipment protection by flameproof enclosures "d" GB 3836.20-2010 Explosive atmospheres.Part 20:Equipment with equipment protection level(EPL)Ga GB 3836.3-2010 Explosive atmospheres.Part 3:Equipment protection by increased safety "e" GB 3836.4-2010 Explosive atmospheres.Part 4:Equipment protection by intrinsic safety "i" GB 3836.5-2004 Electrical apparatus for explosive gas atmosphere-Part 5:Pressurized enclosures"p" GB 3836.6-2004 Electrical apparatus for explosive gas atmospheres-Part 6:Oil-immersion"o" GB 3836.7-2004 Electrical apparatus for explosive gas atmospheres-Part 7:Power filling"q" GB 3836.8-2014 Explosive atmospheres.Part 8: Equipment protection by type of protection “n” GB 3836.9-2014 Explosive atmospheres.Part 9:Equipment protection by type of protection "m"