Biological evaluation of medical devices - Part 10: Tests for irritation and skin sensitization (ISO 10993-10:2010); German version EN ISO 10993-10:2010

ICS
11.100.20
CCS
C30
发布
2010-12
实施

Biological evaluation of medical devices - Part 13: Identification and quantification of degradation products from polymeric medical devices (ISO 10993-13:2010); German version EN ISO 10993-13:2010

ICS
11.100.20
CCS
C30
发布
2010-11
实施

This part of ISO 10993 provides general requirements for the design of tests in a simulated environment for identifying and quantifying degradation products from finished polymeric medical devices ready for clinical use. This part of ISO 10993 describes two test methods to generate degradation products, an accelerated degradation test as a screening method and a real-time degradation test in a simulated environment. For materials that are intended to polymerize in situ, the set or cured polymer is used for testing. The data generated are used in the biological evaluation of the polymer. This part of ISO 10993 considers only nonresorbable polymers. Similar but appropriately modified procedures may be applicable for resorbable polymers. This part of ISO 10993 considers only those degradation products generated by a chemical alteration of the finished polymeric device. It is not applicable to degradation of the device induced during its intended use by mechanical stress, wear or electromagnetic radiation or biological factors such as enzymes, other proteins and cellular activity. NOTE An informative text discussing environmental stress cracking (ESC) of polymers is included as a potential aid to the design of degradation studies (see Annex B). The biological activity of the debris and soluble degradation products is not addressed in this part of ISO 10993, but should be evaluated according to the principles of ISO 10993-1, ISO 10993-16 and ISO 10993-17. Because of the wide range of polymeric materials used in medical devices, no specific analytical techniques are identified or given preference. No specific requirements for acceptable levels of degradation products are provided in this part of ISO 10993.

Biological evaluation of medical devices. Part 13: Identification and quantification of degradation products from polymeric medical devices

ICS
11.100.20
CCS
C37
发布
2010-10-31
实施
2010-10-31

This part of ISO 10993 describes the procedure for the assessment of medical devices and their constituent materials with regard to their potential to produce irritation and skin sensitization. This part of ISO 10993 includes: a) pretest considerations for irritation, including in silico and in vitro methods for dermal exposure; b) details of in vivo (irritation and sensitization) test procedures; c) key factors for the interpretation of the results. Instructions are given in Annex A for the preparation of materials specifically in relation to the above tests. In Annex B several special irritation tests are described for application of medical devices in areas other than skin.

Biological evaluation of medical devices. Tests for irritation and skin sensitization

ICS
11.100.20
CCS
C37
发布
2010-10-31
实施
2010-10-31

This part of ISO 10993 describes the procedure for the assessment of medical devices and their constituent materials with regard to their potential to produce irritation and skin sensitization. This part of ISO 10993 includes: a) pretest considerations for irritation, including in silico and in vitro methods for dermal exposure; b) details of in vivo (irritation and sensitization) test procedures; c) key factors for the interpretation of the results. Instructions are given in Annex A for the preparation of materials specifically in relation to the above tests. In Annex B several special irritation tests are described for application of medical devices in areas other than skin.

Biological evaluation of medical devices - Part 10: Tests for irritation and skin sensitization

ICS
11.100.20
CCS
C30
发布
2010-08-01
实施
2010-08-01

This part of ISO 10993 describes the procedure for the assessment of medical devices and their constituent materials with regard to their potential to produce irritation and skin sensitization

Biological evaluation of medical devices - Part 10: Tests for irritation and skin sensitization

ICS
11.100.20
CCS
发布
2010-08-01
实施

Biological evaluation of medical devices - Part 5 : tests for in vitro cytotoxicity.

ICS
11.100.20
CCS
C37
发布
2010-07-01
实施
2010-07-02

Biological evaluation of medical devices - Part 16 : toxicokinetic study design for degradation products and leachables.

ICS
11.100.20
CCS
C37
发布
2010-07-01
实施
2010-07-09

This part of ISO 10993 provides general principles for the systematic evaluation of the potential and observed biodegradation of medical devices and for the design and performance of biodegradation studies. Information obtained from these studies can be used in the biological evaluation described in the ISO 10993 series. This part of ISO 10993 considers both non-resorbable and resorbable materials. This part of ISO 10993 is not applicable to: a) evaluation of degradation which occurs by purely mechanical processes; methodologies for the production of this type of degradation product are described in specific product standards, where available; b) leachable components which are not degradation products; c) medical devices or components that do not contact the patient's body directly or indirectly. NOTE 2 This part of ISO 10993 can be applied to the degradation of materials used in any kind of product that falls within the definition of “medical device” in ISO 10993-1, even if such products are subject to different regulations from those applying to medical devices, e.g. the scaffold in a tissue engineered medical product, or a carrier matrix to deliver drugs or biologics.

Biological evaluation of medical devices - Framework for identification and quantification of potential degradation products

ICS
11.100.20
CCS
C30
发布
2010-06-30
实施
2010-06-30

This part of ISO 10993 describes: - the general principles governing the biological evaluation of medical devices within a risk management process; - the general categorization of devices based on the nature and duration of their contact with the body; - the evaluation of existing relevant data from all sources; - the identification of gaps in the available data set on the basis of a risk analysis; - the identification of additional data sets necessary to analyse the biological safety of the medical device; - the assessment of the biological safety of the medical device. This part of ISO 10993 does not cover testing of materials and devices that do not come into direct or indirect contact with the patient's body, nor does it cover biological hazards arising from any mechanical failure. Other parts of ISO 10993 cover specific tests, as indicated in the Foreword.

Biological evaluation of medical devices - Evaluation and testing within a risk management process

ICS
11.100.20
CCS
C37
发布
2010-06-30
实施
2010-06-30

Biological evaluation of medical devices — Part 1: Evaluation and testing within a risk management process

ICS
11.100.20
CCS
C37
发布
2010-06-15
实施

This part of ISO 10993 provides general requirements for the design of tests in a simulated environment for identifying and quantifying degradation products from finished polymeric medical devices ready for clinical use

Biological evaluation of medical devices - Part 13: Identification and quantification of degradation products from polymeric medical devices (ISO 10993-13:2010)

ICS
11.100.20
CCS
发布
2010-06-01
实施

Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process; Technical Corrigendum 1

ICS
11.100.20
CCS
C30
发布
2010-06
实施

This part of ISO 10993 provides general requirements for the design of tests in a simulated environment for identifying and quantifying degradation products from finished polymeric medical devices ready for clinical use. This part of ISO 10993 describes two test methods to generate degradation products, an accelerated degradation test as a screening method and a real-time degradation test in a simulated environment. For materials that are intended to polymerize in situ, the set or cured polymer is used for testing. The data generated are used in the biological evaluation of the polymer. This part of ISO 10993 considers only nonresorbable polymers. Similar but appropriately modified procedures may be applicable for resorbable polymers. This part of ISO 10993 considers only those degradation products generated by a chemical alteration of the finished polymeric device. It is not applicable to degradation of the device induced during its intended use by mechanical stress, wear or electromagnetic radiation or biological factors such as enzymes, other proteins and cellular activity.

Biological evaluation of medical devices - Part 13: Identification and quantification of degradation products from polymeric medical devices

ICS
11.100.20
CCS
C30
发布
2010-06
实施

This part of ISO 10993 gives principles on how toxicokinetic studies relevant to medical devices should be designed and performed.

Biological evaluation of medical devices - Part 16: Toxicokinetic study design for degradation products and leachables (ISO 10993-16:2010); German version EN ISO 10993-16:2010

ICS
11.100.20
CCS
C30
发布
2010-06
实施

The role of this part of ISO 10993 is to serve as a framework in which to plan a biological evaluation which, as scientific knowledge advances our understanding of the basic mechanisms of tissue responses, minimizes the number and exposure of test animals by giving preference to chemical constituent testing and in vitro models, in situations where these methods yield equally relevant information to that obtained from in vivo models. It is not intended that this international standard will provide a rigid set of test methods, including pass/fail criteria, as this might result in either an unnecessary constraint on the development and use of novel medical devices, or a false sense of security in the general use of medical devices. Where a particular application warrants it, experts in the product or in the area of application concerned can choose to establish specific tests and criteria, described in a product-specific vertical standard. This part of ISO 10993 is intended for use by professionals, appropriately qualified by training and experience, who are able to interpret its requirements and judge the outcomes of the evaluation for each medical device, taking into consideration all the factors relevant to the device, its intended use and the current knowledge of the medical device provided by review of the scientific literature and previous clinical experience.

Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management system (ISO 10993-1:2009); German version EN ISO 10993-1:2009

ICS
11.100.20
CCS
C30
发布
2010-04
实施

This part of ISO 10993 gives principles on how toxicokinetic studies relevant to medical devices should be designed and performed. Annex A describes the considerations for inclusion of toxicokinetic studies in the biological evaluation of medical devices.

Biological evaluation of medical devices - Toxicokinetic study design for degradation products and leachables

ICS
11.100.20
CCS
C37
发布
2010-03-31
实施
2010-03-31

This part of ISO 10993 provides general requirements for evaluating the interactions of medical devices with blood. It describes a) a classification of medical and dental devices that are intended for use in contact with blood, based on the intended use and duration of contact as defined in ISO 10993-1, b) the fundamental principles governing the evaluation of the interaction of devices with blood, c) the rationale for structured selection of tests according to specific categories, together with the principles and scientific basis of these tests. Detailed requirements for testing cannot be specified because of the limitations in knowledge and precision of tests for interactions of devices with blood. Further, this part of ISO 10993 describes biological evaluation in general terms and may not necessarily provide sufficient guidance for test methods for a specific device. The selection and design of test methods should take into consideration device design, materials, clinical utility, usage environment and risk benefit. This level of specificity can only be covered in vertical standards.

Biological evaluation of medical devices - Selection of tests for interactions with blood

ICS
11.100.20
CCS
C37
发布
2010-02-28
实施
2010-02-28

This part of ISO 10993 gives principles on how toxicokinetic studies relevant to medical devices should be designed and performed. Annex A describes the considerations for inclusion of toxicokinetic studies in the biological evaluation of medical devices.

Biological evaluation of medical devices - Part 16: Toxicokinetic study design for degradation products and leachables

ICS
11.100.20
CCS
C30
发布
2010-02
实施

YY/T 0771的本部分规定了用动物源性材料制造的医疗器械和动物和组织的来源、收集和处置的控制要求,不包括体外诊断医疗器械。YY/T 0771.1给出的风险管理过程要求适用。 YY/T 0771的本部分不包括使用人体组织的医疗器械。 YY/T 0771的本部分未规定医疗器械生产全过程的质量管理体系。

Medical devices utilizing animal tissues and their derivatives.Part 2:Controls on sourcing,collection and handling

ICS
11.100.20
CCS
C30
发布
2009-12-30
实施
2011-06-01