GB 19212.2-2012
Safety of power transformers,power supplies,reactors and similar products.Part 2:Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications (English Version)

GB 19212.2-2012
Standard No.
GB 19212.2-2012
Language
Chinese, Available in English version
Release Date
2012
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB 19212.2-2012
Replace
GB 19212.2-2006
Scope
This chapter of GB 19212.1-2008 is replaced with the following content: This part of GB 19212 specifies the safety regulations for general-purpose separating transformers and power supplies with built-in separating transformers, such as safety regulations on electrical, temperature and mechanical aspects. This section applies to separating transformers and power supplies with built-in separating transformers and electronic circuits. This section does not apply to external circuits and their components intended to be connected to the input and output terminals or output sockets of transformers and power supplies. This section does not apply to transformers included in IEC 60076-11. This section applies to power supplies of stationary or mobile, single-phase or multi-phase, air-cooled (self-cooled or air-cooled), independent or supporting separating transformers and built-in separating transformers, whose rated power supply voltage does not exceed AC 1000V, rated Power frequency and internal operating frequency do not exceed 500Hz. The rated output shall not exceed: --- 1kVA for single-phase separation transformer and single-phase power supply with built-in separation transformer; --- 5kVA for multi-phase power supply with multi-phase separation transformer and built-in separation transformer. When there is an agreement, this section also applies to separation transformers and power supplies with built-in separation transformers that do not limit the rated output. This standard applies to dry-type transformers, the windings of which may be encapsulated or non-encapsulated. No-load output voltage or rated output voltage does not exceed AC 1000V or ripple-free DC 1415V. For independent separation transformers and independent power supplies with built-in separation transformers, the no-load output voltage and/or rated output voltage shall not be lower than AC 50V or ripple-free DC 120V. Isolating transformers covered by this standard are intended for use only where double or reinforced insulation between circuits is not required by installation regulations or end product standards. This section applies to the separation transformers and power supplies with built-in separation transformers associated with a certain command equipment (the scope of which is determined by the relevant technical committee).

GB 19212.2-2012 history

  • 2012 GB 19212.2-2012 Safety of power transformers,power supplies,reactors and similar products.Part 2:Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications
  • 2006 GB 19212.2-2006 Safety of power transformers, power supply units and similar. Part 2: Particular requirements for separating transformers for general use

GB 19212.2-2012 -All Parts

GB 19212.1-2008 Safety of power transformers, power supplies,reactors and similar products.Part 1: General requirements and tests GB 19212.10-2014 Safety of transformers, reactors,power supply units and combinations thereof.Part 10:Particular requirements and tests for transformers and power supply units for class Ⅲ handlamps for tungsten filament lamps GB 19212.13-2005 Safety of power transformers,power supply units and similar devices.Part 13: Particular requirements for constant voltage transformers GB 19212.14-2012 Safety of transformers,reactors,power supply units and similar products for supply voltages up to 1100V.Part 14:Particular requirements and tests for auto transformers and power supply units incorporating auto transformers GB 19212.16-2005 Safety of power transformers,power supply units and similar devices.Part 16: Particular requirements for isolating transformers for supply of medical locations GB 19212.17-2013 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1100 V.Part 17 : Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units GB 19212.18-2006 Safety of power transformers, power supply units and similar. Part 18: Particular requirements for transformers for switch mode power supplies GB 19212.2-2012 Safety of power transformers,power supplies,reactors and similar products.Part 2:Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications GB 19212.20-2008 Safety of power transformers,power supply units and similar.Part 20:Particular requirements for perturbation attenuation transformers GB 19212.21-2014 Safety of transformers,reactors,power supply units and combinations thereof.Part 21:Particular requirements and tests for small reactors GB 19212.24-2005 Safety of power transformers,power supply units and similar devices.Part 24: Particular requirements for transformers for construction sites GB 19212.3-2012 Safety of power transformers,power supplies,reactors and similar products.Part 3:Particular requirements and tests for control transformers and power supplies incorporating control transformers GB 19212.4-2005 Safety of power transformers,power supply units and similar devices.Part 4: Particular requirements for ignition transformers for gas and oil burners GB 19212.5-2011 Safety of transformers,reactors,power supply units and similar products for supply voltages up to 1100 V.Part 5:Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers GB 19212.6-2013 Safety of transformers,reactors,power supply units and combinations thereof.Part 6:Particular requirements and test for transformer for shavers, power supply units for shavers and shaver supply units GB 19212.7-2012 Safety of transformers,reactors,power supply units and similar products for supply voltages up to 1100V.Part 7:Particular requirements and rest for safety isolating transformers and power supply units incorporating safety isolating transformers GB 19212.8-2012 Safety of power transformers,power supplies,reactors and similar products.Part 8:Particular requirements and tests for transformers and power supplies for toys GB 19212.9-2007 Safety of power transformers, power supply units and similar devices Part 9: Particular requirements for bell and chime transformers