GB 19212.17-2013 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1100 V.Part 17 : Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units (English Version)
This standard specifies the safety requirements for switch-mode power supply units and transformers for switch-mode power supply units. Transformers with electronic circuits are also included in this standard. This section applies to: a) Built-in safety isolating transformers, providing AC or DC SELV, PELV or FELV output voltages or some combination of them in accordance with IEC 61140 and IEC 60364-4-41 output voltages, for household and other purposes Switching-mode power supply units for consumer products, other than those covered by IEC 60065, the IEC 61347 series, IEC 61204-7 and IEC 60950-1; b) with a maximum output voltage not exceeding 1000 V a.c. or 1414 V d.c. Switching-mode power supply units for household and other consumer products, except for the products covered in a) and the products covered by IEC 60065, IEC 61347 series, IEC 61204-7 and IEC 60950-1; c) this part can be used for switching Transformers used in type power supply units (see Appendix BB). This section contains safety requirements for: -- corresponding to IEC 61558-2-1 general-purpose isolated SMPS; -- corresponding to IEC 61558-2-4 general-purpose isolated SMPS; -- corresponding to IEC 61558-2- 6 for general purpose safety isolation SMPS;--corresponding to IEC 61558-2-13 for general purpose self-coupling SMPS. For application-specific SMPS corresponding to other Part 2 of the IEC 61558 series, the necessary requirements of the corresponding Part 2 apply. In addition, the requirements listed in this section also apply. If the two requirements conflict, the most stringent requirement takes precedence. This Part includes stationary or mobile, single-phase or multi-phase, air-cooled (natural or forced cooling), independent or supporting switch-mode power supply units, whose rated power supply voltage does not exceed AC 1100 V, and the rated power frequency does not exceed more than 500
GB 19212.17-2013 Referenced Document
GB 19212.1-2008 Safety of power transformers, power supplies,reactors and similar products.Part 1: General requirements and tests
GB/T 16935.4-2011 Insulation coordination for equipment within low-voltage systems.Part 4: Consideration of high-frequency voltage stress
GB/T 16935.5-2008 Insulation coordination for equipment within low-voltage systems.Part 5:Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm
IEC 60227 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 7: Flexible cables screened and unscreened with two or more conductors
IEC 60601-1 Medical electrical equipment - ALL PARTS*, 2023-01-03 Update
IEC 60950-1 Information technology equipment - Safety - Part 1: General
requirements*, 2023-12-09 Update
IEC 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements*, 2017-01-01 Update
IEC 61204-7 Low-voltage switch mode power supplies - Part 7: Safety requirements*, 2016-11-07 Update
IEC 61347 Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps)
IEC 61558-2-1 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-1: Particular requirements and tests for separating transformers and power supply units incorporating separating transformers for general applications*, 2021-04-01 Update
IEC 61558-2-4 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-4: Particular requirements and tests for isolating transformers and power supply units incorporating isolating tr*, 2021-05-18 Update
IEC 61558-2-6 Safety of transformers, reactors, power supply units and combinations thereof - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safet*, 2021-05-18 Update
IEC 62040 Uninterruptible power systems (UPS) - Part 5-3: DC output UPS - Performance and test requirements*, 2016-10-26 Update
GB 19212.17-2013 history
2019GB/T 19212.17-2019 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V—Part 17: Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units
2013GB 19212.17-2013 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1100 V.Part 17 : Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units
2006GB 19212.18-2006 Safety of power transformers, power supply units and similar. Part 18: Particular requirements for transformers for switch mode power supplies
GB 19212.17-2013 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1100 V.Part 17 : Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units has been changed from GB 19212.18-2006 Safety of power transformers, power supply units and similar. Part 18: Particular requirements for transformers for switch mode power supplies.