GB 19212.21-2014
Safety of transformers,reactors,power supply units and combinations thereof.Part 21:Particular requirements and tests for small reactors (English Version)

GB 19212.21-2014
Standard No.
GB 19212.21-2014
Language
Chinese, Available in English version
Release Date
2014
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB 19212.21-2014
Replace
GB 19212.21-2007
Scope
This chapter of GB 19212.1-2008 is replaced by the following: This part of GB 19212 specifies the safety requirements for small reactors for general purposes. Unless otherwise specified, the following "transformers" or "reactors" include small reactors. This section applies to stationary or mobile, single-phase or multi-phase, air-cooled (self-cooled or air-cooled), independent or supporting general-purpose reactors, including AC, pre-excitation and current compensation reactors. The rated power supply voltage shall not exceed AC 1000 V or ripple-free DC 1500 V, and the rated power frequency and internal operating frequency shall not exceed 1 MHz. The rated capacity shall not exceed: -- single-phase reactor, AC 25 kvar (DC 25 kW); -- multi-phase reactor, AC 50 kvar (DC 50 kW). When the purchaser and the manufacturer agree through consultation, this section also applies to reactors without rated capacity restrictions. This section applies to dry-type reactors. Its windings can be encapsulated or non-encapsulated. This section does not apply to: -- Reactors included in IEC 60289; -- Ballasts for tubular fluorescent lamps included in IEC 61347-2-8; -- Discharge lamps included in IEC 61347-2-9 (excluding tubular fluorescent lamps ) with a ballast.

GB 19212.21-2014 Referenced Document

  • GB 19212.21 Safety of transformers,reactors,power supply units and combinations thereof.Part 21:Particular requirements and tests for small reactors
  • GB 19212.21-2014 Safety of transformers,reactors,power supply units and combinations thereof.Part 21:Particular requirements and tests for small reactors
  • Part 2 Basic Specifications for the Manufacture and Installation of Railway Track Scales

GB 19212.21-2014 history

  • 2014 GB 19212.21-2014 Safety of transformers,reactors,power supply units and combinations thereof.Part 21:Particular requirements and tests for small reactors
  • 2007 GB 19212.21-2007 Safety of power transformers, power supply units and simiIar devicesm- Part 21: Particular requirements for small reactors

GB 19212.21-2014 -All Parts

GB 19212.1-2008 Safety of power transformers, power supplies,reactors and similar products.Part 1: General requirements and tests GB 19212.10-2014 Safety of transformers, reactors,power supply units and combinations thereof.Part 10:Particular requirements and tests for transformers and power supply units for class Ⅲ handlamps for tungsten filament lamps GB 19212.13-2005 Safety of power transformers,power supply units and similar devices.Part 13: Particular requirements for constant voltage transformers GB 19212.14-2012 Safety of transformers,reactors,power supply units and similar products for supply voltages up to 1100V.Part 14:Particular requirements and tests for auto transformers and power supply units incorporating auto transformers GB 19212.16-2005 Safety of power transformers,power supply units and similar devices.Part 16: Particular requirements for isolating transformers for supply of medical locations GB 19212.17-2013 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1100 V.Part 17 : Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units GB 19212.18-2006 Safety of power transformers, power supply units and similar. Part 18: Particular requirements for transformers for switch mode power supplies GB 19212.2-2012 Safety of power transformers,power supplies,reactors and similar products.Part 2:Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications GB 19212.20-2008 Safety of power transformers,power supply units and similar.Part 20:Particular requirements for perturbation attenuation transformers GB 19212.21-2014 Safety of transformers,reactors,power supply units and combinations thereof.Part 21:Particular requirements and tests for small reactors GB 19212.24-2005 Safety of power transformers,power supply units and similar devices.Part 24: Particular requirements for transformers for construction sites GB 19212.3-2012 Safety of power transformers,power supplies,reactors and similar products.Part 3:Particular requirements and tests for control transformers and power supplies incorporating control transformers GB 19212.4-2005 Safety of power transformers,power supply units and similar devices.Part 4: Particular requirements for ignition transformers for gas and oil burners GB 19212.5-2011 Safety of transformers,reactors,power supply units and similar products for supply voltages up to 1100 V.Part 5:Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers GB 19212.6-2013 Safety of transformers,reactors,power supply units and combinations thereof.Part 6:Particular requirements and test for transformer for shavers, power supply units for shavers and shaver supply units GB 19212.7-2012 Safety of transformers,reactors,power supply units and similar products for supply voltages up to 1100V.Part 7:Particular requirements and rest for safety isolating transformers and power supply units incorporating safety isolating transformers GB 19212.8-2012 Safety of power transformers,power supplies,reactors and similar products.Part 8:Particular requirements and tests for transformers and power supplies for toys GB 19212.9-2007 Safety of power transformers, power supply units and similar devices Part 9: Particular requirements for bell and chime transformers