EN 60601-2-17-2015

Medical electrical equipment - Part 2-17: Particular requirements for the basic safety and essential performance of automatically-controlled brachytherapy afterloading equipment


 

 

非常抱歉,我们暂时无法提供预览,您可以试试: 免费下载 EN 60601-2-17-2015 前三页,或者稍后再访问。

如果您需要购买此标准的全文,请联系:

点击下载后,生成下载文件时间比较长,请耐心等待......

 

标准号
EN 60601-2-17-2015
发布日期
2015年05月01日
实施日期
2018年07月27日
废止日期
中国标准分类号
/
国际标准分类号
/
发布单位
CENELEC - European Committee for Electrotechnical Standardization
引用标准
54
适用范围
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of automatically-controlled BRACHYTHERAPY AFTERLOADING ME EQUIPMENT@ hereafter referred to as ME EQUIPMENT. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only@ or to ME SYSTEMS only@ the title and content of that clause or subclause will say so. If that is not the case@ the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS@ as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this standard are not covered by specific requirements in this standard except in 7.2.13 and 8.4.1 of the general standard. NOTE See also 4.2 of the general standard. This standard applies to automatically-controlled BRACHYTHERAPY AFTERLOADING ME EQUIPMENT used for treatment or alleviation of disease. This standard specifies requirements a) for automatically-controlled AFTERLOADING ME EQUIPMENT 1) which contains and uses only beta@ gamma@ or NEUTRON-emitting SEALED RADIOACTIVE SOURCES@ or BRACHYTHERAPY X-RAY SOURCES designed and constructed for use with automatically-controlled AFTERLOADING ME EQUIPMENT@ 2) which automatically drives the RADIATION SOURCE(S) from a STORAGE CONTAINER or@ in the case of BRACHYTHERAPY X-RAY SOURCES@ a reference location outside the PATIENT@ to a treatment position inside the SOURCE APPLICATOR(S) and returns the RADIATION SOURCE(S) to the STORAGE CONTAINER or the BRACHYTHERAPY X-RAY SOURCE(S) to the reference location@ 3) which is designed for connection to a PATIENT@ and 4) with which movements of the RADIATION SOURCE(S) are carried out automatically by the ME EQUIPMENT according to a prescribed programme using a powered mechanism whose changes are controlled by the CONTROLLING TIMER(S) and TIMING DEVICES that are either PROGRAMMABLE ELECTRONIC SUB-SYSTEMS (PESS) (computer or microprocessors) or non-programmable systems and b) for ME EQUIPMENT intended to be 1) for NORMAL USE@ operated under the authority of appropriately licensed or QUALIFIED PERSONS by OPERATORS having the required skills for a particular medical application@ for particular specified clinical purposes@ e.g. remote AFTERLOADING BRACHYTHERAPY; 2) maintained in accordance within the recommendations given in the INSTRUCTIONS FOR USE; 3) subject to regular quality assurance performance and calibration checks by a QUALIFIED PERSON. This standard does not specify requirements for SEALED RADIOACTIVE SOURCES. Requirements for the design of X-RAY TUBES used with the ME EQUIPMENT are specified in other IEC standards. See for example: IEC 60601-2-28:2010. The requirements of this standard are based on the assumptions that: ?C a TREATMENT PLAN is available that prescribes appropriate values of the TREATMENT PARAMETERS@ and ?C the SOURCE STRENGTH(S) or the REFERENCE AIR-KERMA RATE of the RADIATION SOURCE(S) used by the ME EQUIPMENT is (are) known. This standard includes requirements intended to ensure that the prescribed values of the TREATMENT PARAMETERS can be achieved by the ME EQUIPMENT@ in particular that: ?C the selected RADIATION SOURCE(S) is (are) positioned or moved within the SOURCE APPLICATOR in the selected configuration relative to the SOURCE APPLICATOR; ?C IRRADIATION is performed by the selected RADIATION SOURCE configuration for the selected duration; ?C IRRADIATION is performed by the ME EQUIPMENT without causing unnecessary RISK to the OPERATOR or other persons in the immediate surroundings.

EN 60601-2-17-2015系列标准

EN 60601-1 A1-2013 EN 60601-1 A1-2013 EN 60601-1 A12-2014 EN 60601-1 A12-2014 EN 60601-1 AC-2010 EN 60601-1 AC-2010 EN 60601-1 prA1-1992 医用电气设备.第1部分:安全的一般规则.(IEC 601-1-88/A1-91) EN 60601-1-1-1993 EN 60601-1-10-2008 医用电气设备.第1-10部分:基本安全和重要性能的一般要求.附属标准:理疗闭环控制器的开发要求 EN 60601-1-11-2015 EN 60601-1-12-2015 EN 60601-1-9-2008 医用电气设备.第1-9部分:基本安全和重要性能的一般要求.附属标准:环境意识设计要求 EN 60601-1-2-2015 EN 60601-1-3-2008 医用电气设备.第1-3部分:基本安全和重要性能的一般要求.附属标准:诊断X射线设备中辐射防护;合并勘误表2010年3月 EN 60601-1-4-1996 EN 60601-1-6-2010 医用电气设备.第1-6部分:基本安全和重要性能的一般要求.附属标准:可用性 EN 60601-1-8 A11-2017 EN 60601-1-8 A11-2017 EN 60601-1-8-2007 医用电气设备.第1-8部分:基本安全和重要性能的一般要求.附属标准:医用电气设备和医用电气系统的报警设备的一般要求,试验和导则 EN 60601-1-9-2008 医用电气设备.第1-9部分:基本安全和重要性能的一般要求.附属标准:环境意识设计要求 EN 60601-2-1-2015 EN 60601-2-10-2015 EN 60601-2-11-2015 EN 60601-2-12-2006 EN 60601-2-13-2006 EN 60601-2-16-2015 EN 60601-2-17/A1-1996 EN 60601-2-18-2015 EN 60601-2-19-2009 医用电气设备.第2-19部分:婴儿培养箱基本安全和主要性能的特殊要求 EN 60601-2-2-2009 医用电气设备.第2-2部分:高频手术设备和高频外科手术附件基本安全和主要性能的特殊要求 EN 60601-2-20-2009 医用电气设备.第2-20部分:婴儿运输培养箱基本安全和主要性能的特殊要求 EN 60601-2-21-2009 医用电气设备.第2-21部分:婴儿保温箱基本安全和主要性能的特殊要求 EN 60601-2-22-2013 EN 60601-2-23-2015 EN 60601-2-24-2015 EN 60601-2-25-2015 EN 60601-2-26-2015 EN 60601-2-27-2014 EN 60601-2-28-2010 医用电气设备.第2-28部分:医用诊断用X射线管组件基本安全和主要性能的特殊要求 EN 60601-2-29-2008 EN 60601-2-29/A1-1996 EN 60601-2-3-2015 EN 60601-2-30-2000 EN 60601-2-31-2008 医用电气设备.第2-31部分:用内供电源的体外心脏起博器基本安全和主要性能的特殊要求 EN 60601-2-32-1994 EN 60601-2-33-2010 医疗电气设备.第2-33部分:医疗诊断用磁共振设备的基本安全和必要性能特殊要求 EN 60601-2-34-2014 EN 60601-2-35-1996 EN 60601-2-36-2015 EN 60601-2-37-2008 医用电气设备.第2-37部分:医用超声诊断和监护设备基本安全和主要性能的特殊要求 EN 60601-2-38-1996 EN 60601-2-39-2008 EN 60601-2-4-2011 医疗电气设备.第2-4部分:心脏除颤器的基本安全和必要性能特殊要求 EN 60601-2-40-1998 医疗电气设备.第2-40部分:肌电图仪和激发响应设备安全的特殊要求 IEC 60601-2-40-1998 EN 60601-2-41-2009 医用电气设备.第2-41部分:外科手术灯和诊断用灯安全性的基本安全性和主要性能专门要求 EN 60601-2-43-2010 医用电气设备.第2-43部分:介入过程用X射线设备的基本安全和主要性能用特殊要求[:CENELEC EN 60601-2-54] EN 60601-2-44-2009 医用电气设备.第2-44部分:X线断层摄影术计算用X射线设备的基本安全和主要性能用专用要求 EN 60601-2-45-2011 EN 60601-2-46-2011 医疗电气设备.第2-46部分:手术台的基本安全和必要性能特殊要求 EN 60601-2-47-2015 EN 60601-2-49-2015 EN 60601-2-5-2015 EN 60601-2-50-2009 医用电气设备.第2-50部分:婴儿光疗设备基本安全和主要性能的专门要求 EN 60601-2-51-2003 医用电气设备.第2-51部分:单道和多道心电描记器记录和分析的安全性的特殊要求 IEC 60601-2-51-2003 EN 60601-2-52-2010 医用电气设备.第2-52部分:医用病床的基本安全及主要性能的专门要求[替代:CEN EN 1970,CENELEC EN 60601-2-38] EN 60601-2-54-2009 EN 60601-2-57-2011 医疗电气设备.第2-57部分:用于治疗,诊断,监控和化妆/美学的非激光光源设备的基本安全和必要性能特殊要求 EN 60601-2-6-2015 EN 60601-2-62-2015 EN 60601-2-63-2015 EN 60601-2-64-2015 EN 60601-2-65-2013 EN 60601-2-66-2015 EN 60601-2-68-2015 EN 60601-2-7-1998 EN 60601-2-8-2015 EN 60601-2-9-1996 医用电气设备.第2部分:用于放射治疗与患者接触且具有电气连接辐射探测器的剂量计的安全专用要求;合并勘误表1996年12月 IEC 601-2-9-1996 EN 60601-3-1-1996

谁引用了EN 60601-2-17-2015 更多引用





Copyright ©2007-2022 ANTPEDIA, All Rights Reserved
京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号