GB 19212.1-2003
Safety of power transformers,power supply units and similar--Part 1: General requirements and tests

2009-06
Standard No.
GB 19212.1-2003
Language
Chinese
Release Date
2003
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Replace By
GB 19212.1-2008
GB 19212.21-2007
Lastest
GB/T 19212.11-2020
Scope
This part of GB l9212 specifies the safety requirements for the following transformers in various aspects (such as electrical, thermal and mechanical aspects): a) Stationary or mobile, single-phase or multi-phase, air-cooled (natural cooling or forced cooling), supporting Isolation transformers and safety isolation transformers for use or other applications, the rated power supply voltage is not greater than 1000 V AC, the rated frequency is not greater than 1 MHz, and the rated output is not greater than the following specified values: Note 1: For higher frequencies, this part can be used as Guidance documents to use. For isolation transformers: - single-phase transformers, 25 kVA; - multi-phase transformers, 40 kVA. For safety isolation transformers: - single-phase transformers, 10 kVA; - multi-phase transformers, 16 kVA. The no-load output voltage and the rated output voltage are not greater than: ——For isolation transformers, AC 500 V and ripple-free DC 708 V. Note 2: For isolation transformers, the no-load rated output voltage can be as high as AC 1000V or ripple-free DC 1415V in accordance with the national wiring regulations or in the case of special purposes. - For safety isolating transformers, between two conductors or between any one conductor and the ground, AC rms value 50 V and (or) ripple-free DC 120 V. Note 3: Use isolation transformers or safety isolation transformers when installation regulations or electrical appliances (such as electric toys, electric bells, mobile electric tools, portable lamps) require double insulation or reinforced insulation between circuits. For each type of transformer, its rating is specified in the relevant special requirements in other parts of GB 19212. B) Standing or mobile, single-phase or multi-phase, air cooling (natural cooling or forced cooling), supporting or non-supporting separation transformers, autotransformers, voltage regulators and small reactors, their rated power A voltage not exceeding 1000 V a.c., a rated frequency not exceeding 1 MHz, a rated no-load and loaded output voltage not exceeding 15 kV a.c. or d.c., or, for stand-alone transformers, not exceeding 50 V a.c. and/or 120 V d.c. without ripple, and Unless otherwise specified in the relevant special requirements of other parts of GB 19212, the rated output shall not exceed the following specified values: ——Single-phase transformer, 1 kVA ——Single-phase reactor, 2 kVAR ——Multiphase transformer, 5 kVA —— Polyphase reactor, 10 kVAR Note 1: Isolating transformers are used where installation procedures or equipment specifications do not require double or reinforced insulation between circuits. Note 2: As the transformer technology develops, it may mean that higher rated frequency limits need to be increased. Note 3 to entry: Normally, a transformer is intended to be used with equipment to provide the function of the equipment with a voltage different from the mains supply. Safety insulation may be provided (or achieved) by other features of the device, such as the housing. Components of the output circuit may be connected to the input circuit or to protective earth. C) Power supply unit fitted with a transformer of type a) or b). Note 1 to entry: This power supply unit may include transformers, rectifiers, converters, frequency converters or combinations thereof intended to supply power to electrical equipment, except switching power supplies. Note 2 to entry: Examples of power supply units are built-in or separate transformers, secondary batteries and converters. In the latter case, they may even be provided with integral pins intended to be inserted into fixed socket-outlets. Note 3: The requirements for transformers for switching power supplies are specified in GB l921

GB 19212.1-2003 history

  • 2020 GB/T 19212.11-2020 Safety of transformers, reactors, power supply units and combinations thereof—Part 11: Particular requirements and tests for separating transformers with high insulation level and separating transformers with output voltages exceeding 1 000 V
  • 2016 GB/T 19212.1-2016 Safety of transformers, reactors,power supply units and combinations thereof—Part 1: General requirements and tests
  • 2008 GB 19212.1-2008 Safety of power transformers, power supplies,reactors and similar products.Part 1: General requirements and tests
  • 2003 GB 19212.1-2003 Safety of power transformers,power supply units and similar--Part 1: General requirements and tests

GB 19212.1-2003 -All Parts

GB 19212.1-2008 Safety of power transformers, power supplies,reactors and similar products.Part 1: General requirements and tests GB 19212.10-2014 Safety of transformers, reactors,power supply units and combinations thereof.Part 10:Particular requirements and tests for transformers and power supply units for class Ⅲ handlamps for tungsten filament lamps GB 19212.13-2005 Safety of power transformers,power supply units and similar devices.Part 13: Particular requirements for constant voltage transformers GB 19212.14-2012 Safety of transformers,reactors,power supply units and similar products for supply voltages up to 1100V.Part 14:Particular requirements and tests for auto transformers and power supply units incorporating auto transformers GB 19212.16-2005 Safety of power transformers,power supply units and similar devices.Part 16: Particular requirements for isolating transformers for supply of medical locations GB 19212.17-2013 Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1100 V.Part 17 : Particular requirements and tests for switch mode power supply units and transformers for switch mode power supply units GB 19212.18-2006 Safety of power transformers, power supply units and similar. Part 18: Particular requirements for transformers for switch mode power supplies GB 19212.2-2012 Safety of power transformers,power supplies,reactors and similar products.Part 2:Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications GB 19212.20-2008 Safety of power transformers,power supply units and similar.Part 20:Particular requirements for perturbation attenuation transformers GB 19212.21-2014 Safety of transformers,reactors,power supply units and combinations thereof.Part 21:Particular requirements and tests for small reactors GB 19212.24-2005 Safety of power transformers,power supply units and similar devices.Part 24: Particular requirements for transformers for construction sites GB 19212.3-2012 Safety of power transformers,power supplies,reactors and similar products.Part 3:Particular requirements and tests for control transformers and power supplies incorporating control transformers GB 19212.4-2005 Safety of power transformers,power supply units and similar devices.Part 4: Particular requirements for ignition transformers for gas and oil burners GB 19212.5-2011 Safety of transformers,reactors,power supply units and similar products for supply voltages up to 1100 V.Part 5:Particular requirements and tests for isolating transformers and power supply units incorporating isolating transformers GB 19212.6-2013 Safety of transformers,reactors,power supply units and combinations thereof.Part 6:Particular requirements and test for transformer for shavers, power supply units for shavers and shaver supply units GB 19212.7-2012 Safety of transformers,reactors,power supply units and similar products for supply voltages up to 1100V.Part 7:Particular requirements and rest for safety isolating transformers and power supply units incorporating safety isolating transformers GB 19212.8-2012 Safety of power transformers,power supplies,reactors and similar products.Part 8:Particular requirements and tests for transformers and power supplies for toys GB 19212.9-2007 Safety of power transformers, power supply units and similar devices Part 9: Particular requirements for bell and chime transformers



Copyright ©2007-2023 ANTPEDIA, All Rights Reserved