GB 16915.2-2012
Switches for household and similar fixed electrical installations.Part 2-1:Particular requirements.Electronic switches (English Version)

GB 16915.2-2012
Standard No.
GB 16915.2-2012
Language
Chinese, Available in English version
Release Date
2012
Published By
General Administration of Quality Supervision, Inspection and Quarantine of the People‘s Republic of China
Latest
GB 16915.2-2012
Replace
GB 16915.2-2000
Scope
This chapter in GB 16915.1 is changed to the following: This part specifies the classification, protection against electric shock, grounding measures, structural requirements, mechanical properties and electrical properties of electronic switches and related electronic auxiliary devices for household and similar fixed electrical installations This part of GB 16915 applies to electronic switches and related electronic auxiliary devices for household and similar fixed electrical installations for indoor or outdoor use. This part applies to operating lighting circuits, controlling the brightness of lamps (adjustment electrical switches), electronic switches for controlling the speed of electric motors (for example, for exhaust fans, etc.) and for other purposes (for example, heating control), the rated voltage of these switches not exceeding 250 V a.c. and the rated current not exceeding 16 A. The operation and/or control of the device is artificially achieved by means of touch, proximity, rotation, light, sound, heat or other influences through the actuating element, sensing surface and sensing device. This section is also applicable to general purposes Electronic switches with built-in automatic functions, the operation and/or control of which are stimulated by changes in physical quantities, such as light, temperature, humidity, time, wind speed, human presence, etc. This part also Suitable for mounting boxes for electronic switches, except those for concealed electronic switches. This standard also applies to electronic remote control switches (RCS) and electronic time-delay switches (TDS), the rated voltage of which does not exceed 440 V and the rated current of which does not exceed Household and similar fixed electrical installations exceeding 25 A, intended for indoor or outdoor use, electronic switches complying with this standard are suitable for use in ambient temperatures which normally do not exceed 35°C, occasionally reaching 40°C, in special conditions, such as on ships, vehicles and the like, and in hazardous locations (e.g. where explosions may occur), may require special structures,

GB 16915.2-2012 Referenced Document

  • GB 13140.2 Connecting devices for low-voltage circuits for household and similar purposes.Part 2:Particular requirements for connecting devices as separate entities with screw-type clamping units
  • GB 14536.1 Automatic electrical controls for household and similar use.Part 1:General requirements
  • GB 14536.10 Automatic electrical controls for household and similar use.Particular requirements for temperature sensing controls
  • GB 14536.11 Automatic electrical controls for household and similar use.Particular requirements for motor-starting relays
  • GB 14536.12 Automatic electrical controls for household and similar use.Particular requirements for energy regulators
  • GB 14536.13 Automatic electrical controls for household and similar use.Particular requirements for electrically operated door locks
  • GB 14536.14 Automatic electrical controls for household and similar use. Particular requirements for household washing machine microcomputer controller
  • GB 14536.15 Automatic electrical controls for household and similar use.Particular requirements for humidity sensing controls
  • GB 14536.16 Automatic electrical controls for household and similar use.Particular requirements for electric actuators*2013-12-17 Update
  • GB 14536.17 Automatic electrical controls for household and similar use Particular requirements for automatic electrical water level sensing controls of the float or electrode-sensor type used in boiler applications
  • GB 14536.18 Automatic electrical controls for household and similar use Particular requirements for automatic electrical water level controls of the float type for household and similar applications
  • GB 14536.19 Automatic electrical controls for household and similar use Particular requirements for electrically operated gas valves,including mechanical requirements
  • GB 14536.2 Automatic electrical controls for household and similar use. Particular requirements for electrical controls for electrical household appliances
  • GB 14536.20 Automatic electrical controls for household and similar use.Particular requirements for automatic electric water and air flow sensing controls,including mechanical requirements
  • GB 14536.21 Automatic electrical controls for household and similar use.Particular requirements for electrically operated oil valves,including mechanical requirements
  • GB 14536.3 Automatic electrical controls for household and similar use.Particular requirements for thermal motor protectors
  • GB 14536.4 Automatic electrical controls for household and similar use.Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps
  • GB 14536.5 Automatic electrical controls for household and similar use.Particular requirements for thermal motor protectors for motor-compressors of hermetic and semi-hermetic type
  • GB 14536.6 Automatic electrical controls for household and similar use.Particular requirements for automatic electrical burner control systems
  • GB 14536.7 Automatic electrical controls for household and similar use.Particular requirements for automatic electrical pressure sensing controls including mechanical requirements
  • GB 14536.8 Automatic electrical controls for household and similar use.Particular requirements for timers and time switches
  • GB 14536.9 Automatic electrical controls for household and similar use.Particular requirements for electrically operated water valves,including mechanical requirements
  • GB 16915.1 Switches for household and similar fixed-electrical installations.Part 1:General requirements*2014-09-03 Update
  • GB 16915.3-2000 Switches for household and similar fixed electrical installations--Part 2: Particular requirements--Section 2: Remote-control switches(RCS)
  • GB 16915.4-2003 Switches for household and similar fixed-electrical installations--Part 2: Particular requirements Section 3: Time-delay switches(TDS)
  • GB 17625.1-2003 Electromagnetic compatibility limits Limits for harmonic current emissions(equipment input current≤16 A per phase
  • GB 17625.2-2007 Electromagnetic compatibility (EMC).Limits.Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤16A per phase and not subject to conditional connection
  • GB 4343 Limies and methods of measurement of radio disturbance characteristics of electrical motor-operated and thermal appliances for house-hold and similar purposes, electric tools and similar electric apparatus
  • GB 8898-2011 Audio, video and similar electronic apparatus.Safety requirements
  • GB 9364.1 Miniature fuses. Part 1: Definitions for miniature fuses and general requirement for miniature fuse-links
  • GB 9364.2 Miniature fuses. Part 2: Cartridge fuse-links
  • GB 9364.3 Miniature fuses. Part 3: Sub-miniature fuse-links
  • GB 9364.4 Miniature fuses. Part 4: Universal modular fuse-links (UMF)
  • GB 9364.6 Miniature fuses--Part 6: Fuse-holders for miniature cartridge fuse-links
  • GB/T 11021-2007 Electrical insulation.Thermal classification
  • GB/T 14472-1998 Fixed capacitors for use in electronic equipment. Part 14: Sectional specification. Fixed capacitors for electromagnetic interference suppression and connection to the supply mains
  • GB/T 1633-2000 Plastics--Thermoplastic materials--Determination of vicat softening temperature(VST)
  • GB/T 16842 Protection of persons and equipment by enclosures.Probe for verification*2016-02-24 Update
  • GB/T 16935.1-2008 Insulation coordination for equipment within low-voltage systems.Part 1:Principles,requirements and tests
  • GB/T 16935.3 Insulation coordination for equipment within low-voltage systems.Part 3:Use of coating, potting or moulding for protection against pollution*2016-04-25 Update
  • GB/T 5023.5 Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V.Part 5:Flexible cables(cords)
  • GB/T 6109.1 Enamelled round winding wires Part 1: General provisions
  • GB/T 6109.1-2008 Enamelled round winding wires - Part 1: General provisions
  • GB/T 6109.10 Enamelled round winding were.Part 10:Solderable polyurethane enamelled round copper wire,class 155
  • GB/T 6109.11 Enamelled round winding wire.Part 11:Solderable polyurethane enamelled round copper wire overcoated with polyamide,class 155
  • GB/T 6109.12 Enamelled round winding wire.Part 12:Polyesteror polyesterimide enamelled round copper wire overcoated with polyamide,class 180
  • GB/T 6109.13 Enamelled round winding wire.Part 13:Solderable polyesterimide enamelled round copper wire,class 180
  • GB/T 6109.14 Enamelled round winding wire.Part 14:Polyamide-ide enamelled round copper wire,class 200
  • GB/T 6109.15 Enamelled round winding wire.Part 15:Solderable polyurethane enamelled round copper wire,class 130,with a bonding layer
  • GB/T 6109.16 Enamelled round winding wire.Part 16:Solderable polyurethane enamelled round copper wire,class 155,with a bonding layer
  • GB/T 6109.17 Enamelled round winding wire.Part 17:Solderable polyesterimide enamelled round copper wire,class 180,with a bonding layer
  • GB/T 6109.18 Enamelled round winding wire.Part 18:Polyesterimide enamelled round copper wire,class 180,with a bonding layer
  • GB/T 6109.19 Enameled round winding wire.Part 19:Polyester or polyesterimide overcoated with polyamide-imide enamelled round copper wire,class 200,with a bonding layer
  • GB/T 6109.2 Enamelled round winding wire.Part 2:Polyester enamelled round copper wire,class 155
  • GB/T 6109.20 Enamelled round winding wire.Part 20:Polyester or polyesterimide overcoated with polyamide-imide enamelled round copper wire,class 200
  • GB/T 6109.21 Enamelled round winding wire.Part 21:Polyester-amide-imide enamelled round copper wire,class 200
  • GB/T 6109.22 Enamelled round winding wire.Part 22:Aromatic polyimide enamelled round copper wire,class 240
  • GB/T 6109.23 Enamelled round winding wire.Part 23:Solderable polyurethane enamelled round copper wire,class 180
  • GB/T 6109.3 Enamelled round winding wire.Part 3:Polyvinyl acetal enamelled round copper wire,class 120
  • GB/T 6109.4 Enamelled round winding wire.Part 4:Solderable polyurethane enamelled round copper wire,class 130
  • GB/T 6109.5 Enamelled round winding wire.Part 5:Polyesterimide enamelled round copper wire,class 180
  • GB/T 6109.6 Enamelled round winding wire.Part 6:Polyimide enamelled round copper wire,class 220
  • GB/T 6109.7 Enamelled round winding wire.Part 7:Polyester enamelled round copper wire,class 130L
  • GB/T 6109.8 Enamelled round winding wires--Part 8: Heat or solvent bonding polyester enamelled round copper wires
  • GB/T 6109.9 Enamelled round winding wire.Part 9:Solderable polyurethane enamelled round copper wire overcoated with polyamide,class130

GB 16915.2-2012 history

  • 2012 GB 16915.2-2012 Switches for household and similar fixed electrical installations.Part 2-1:Particular requirements.Electronic switches
  • 2000 GB 16915.2-2000 Switches for household and similar fixed-electrical installations. Part 2: Particular requirements. Section 1: Electronic switches

GB 16915.2-2012 -All Parts